ICES, an expert system for the set-up and interpretation of a ruggedness test in HPLC method validation Part 1: The ruggedness test in HPLC method validation
نویسندگان
چکیده
Van Leeuwen, J.A., Buydens, L.M.C., Vandeginste, B.G.M., Kateman, G., Schoenmakers, P.J. and Mulholland, M. 1991. RES, an expert system for the set-up and inte~retation of a ruggedness test in HPLC method validation. Part 1: The ruggedness test in HPLC method validation. Chemomeirics and Intelligent Lnboratory Systems, 10: 331-347. In method validation, an intralaboratory repeatability study and an interlaboratory reproducibility study can be performed as part of a precision test. In HPLC, an intralaborato~ ruggedness test can be performed to detect problems that would otherwise be encountered in a reproducibility study. In a ruggedness test, variations in ambient factors that are expected to occur in practice, are simulated. Several steps determine the success of a ruggedness test. The complexity and lack of standard procedures for some of these steps is the main reason why ruggedness testing is still not widely accepted.
منابع مشابه
RES, an expert system for the set-up and interpretation of a ruggedness test in HPLC method validation Part 2: The ruggedness expert system
متن کامل
RES, an expert system for the set-up and interpretation of a ruggedness test in HPLC method validation Part 3: The evaluation
متن کامل
Development and Validation of RP-HPLC-UV Method for Determination of Diclofenac Sodium Residues on Surfaces for Cleaning Validation
In recent years, cleaning validation has achieved a position of increasing in the pharmaceutical industry. It provides assurance to the cleaning procedure that ensures equipment is consistently cleaned from the product, detergent and microbial residues to an acceptable level to avoid cross-contamination and adulteration of drug product with other active ingredients. The aim of this study was to...
متن کاملStrategy for ruggedness tests in chromatographic method validation
The search for sources from which small changes have an in ̄uence on the response of an analytical system, the ruggedness test, has become an essential part of a validation study. However, the `de®nition' of ruggedness and how to perform a ruggedness test are still ambiguous. In this paper a strategy is proposed to perform a ruggedness test for chromatographic methods. Because the strategy is ba...
متن کاملDevelopment and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.
AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm 4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...
متن کامل