Designs and performance of microprocessor-controlled knee joints.

نویسندگان

  • Julius Thiele
  • Bettina Westebbe
  • Malte Bellmann
  • Marc Kraft
چکیده

In this comparative study, three transfemoral amputee subjects were fitted with four different microprocessor-controlled exoprosthetic knee joints (MPK): C-Leg, Orion, Plié2.0, and Rel-K. In a motion analysis laboratory, objective gait measures were acquired during level walking at different velocities. Subsequent technical analyses, which involved X-ray computed tomography, identified the functional mechanisms of each device and enabled corroboration of the performance in the gait laboratory by the engineering design of the MPK. Gait measures showed that the mean increase of the maximum knee flexion angle at different walking velocities was closest in value to the unaffected contralateral knee (6.2°/m/s) with C-Leg (3.5°/m/s; Rel-K 17.0°/m/s, Orion 18.3°/m/s, and Plié2.0 28.1°/m/s). Technical analyses corroborated that only with Plié2.0 the flexion resistances were not regulated by microprocessor control at different walking velocities. The muscular effort for the initiation of the swing phase, measured by the minimum hip moment, was found to be lowest with C-Leg (-82.1±14.1 Nm; Rel-K -83.59±17.8 Nm, Orion -88.0±16.3 Nm, and Plié2.0 -91.6±16.5 Nm). Reaching the extension stop at the end of swing phase was reliably executed with both Plié2.0 and C-Leg. Abrupt terminal stance phase extension observed with Plié2.0 and Rel-K could be attributed to the absence of microprocessor control of extension resistance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative biomechanical analysis of current microprocessor-controlled prosthetic knee joints.

OBJECTIVE To investigate and identify functional differences of 4 microprocessor-controlled prosthetic knee joints (C-Leg, Hybrid Knee [also called Energy Knee], Rheo Knee, Adaptive 2). DESIGN Tested situations were walking on level ground, on stairs and ramps; additionally, the fall prevention potentials for each design were examined. The measuring technology used included an optoelectronic ...

متن کامل

Malte Bellmann and Marc Kraft Designs and performance of microprocessor - controlled knee joints

In this comparative study, three transfemoral amputee subjects were fitted with four different microprocessor-controlled exoprosthetic knee joints (MPK): C-Leg, Orion, Plié2.0, and Rel-K. In a motion analysis laboratory, objective gait measures were acquired during level walking at different velocities. Subsequent technical analyses, which involved X-ray computed tomography, identified the func...

متن کامل

Biomechanical Investigation of Currently Available Microprocessor Controlled Prosthetic Feet: First Results

Since the introduction of microprocessor controlled knee joints in the nineties their market share has constantly increased. Advantages such as the functional range and the safety have been proven repeatedly. These knee joints are accepted by users and technicians and have become an indispensable part of today's prosthetic treatment options of the lower limb. Considering, however, the developme...

متن کامل

Author ' s response to reviews Title : Measures and procedures utilized to determine the added value of microprocessor - controlled prosthetic knee joints : a systematic review

Title: Measures and procedures utilized to determine the added value of microprocessor-controlled prosthetic knee joints: a systematic review

متن کامل

Influence of advanced prosthetic knee joints on perceived performance and everyday life activity level of low-functional persons with a transfemoral amputation or knee disarticulation.

OBJECTIVE To assess the effects of two types of microprocessor-controlled prosthetic knee joints (MPKs) on perceived performance and everyday life activity level. DESIGN Randomized cross-over trial. SUBJECTS Thirty persons with a unilateral above-knee amputation or knee disarticulation classified as Medicare Functional Classification Level-2. METHODS Participants were measured in 3 condit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedizinische Technik. Biomedical engineering

دوره 59 1  شماره 

صفحات  -

تاریخ انتشار 2014