On the differences between two-dimensional and three-dimensional simulations for assessing elastographic image quality: a simulation study.
نویسندگان
چکیده
In this work, we introduced an elastographic simulation framework, which estimates upper bounds on elastographic image quality by accounting for three-dimensional (3D) tissue motion and the 3D nature of the ultrasound beam. For the boundary conditions and the range of applied strains considered in this study, it was observed that for applied strains smaller than 0.7%, fast two-dimensional (2D) simulations and 3D simulations predicted similar upper bounds on elastographic signal-to-noise (SNR(e)) and contrast-to-noise ratios (CNR(e)); however, for applied strains greater than 0.7%, the predictions by 2D simulations grossly overestimated the achievable results when compared with upper bound results from 3D simulations. It was also found that linear increments in the elevational-to-lateral beamwidth ratio (beam ratio) resulted in nonlinear degradation in the achievable upper bounds on elastographic signal-to-noise ratio. For the modulus contrast ratio of ten between the target and the background, the peak difference in the prediction of contrast-to-noise by 2D and 3D simulations was approximately 10 dB, whereas, for modulus contrast ratio of 1.5, the peak difference increased to approximately 30 dB. No significant difference was observed between the spatial resolution predicted by 2D and 3D simulations; however, increase in beam ratio resulted in decrease in target detectability, especially at lower modulus contrast ratios.
منابع مشابه
Three-dimensional simulation of human teeth and its application in dental education and research
Background: A comprehensive database, comprising geometry and properties of human teeth, is needed for dentistry education and dental research. The aim of this study was to create a three-dimensional model of human teeth to improve the dental E-learning and dental research. Methods: In this study, a cross-section picture of the three-dimensional model of the teeth was used. CT-Scan im...
متن کاملPossibility and Reproducibility of Renal Assessing and Size Measurement by Three- Dimensional vs Two- Dimensional Ultrasounographv in Dogs
Objective- To determine the possibility and reproducibility of three-dimensional ultrasonography (3DUS)and comparison of the achieved measurements to normal two-dimensional ultrasonography (2DCS)Design- Descriptive studyAnimals- 10 young mixed normal dogs, age 1.5-2.5 year, weighing 9.7-12 kg Procedure- Renal width, length, and depth measured in coron al and transverse sections. The measurement...
متن کاملشبیه سازی ذوب سیستمهای دو بعدی
The study of a two-dimensional (2-D) system started nearly half a century ago when Peierls and Landau showed the lack of long range translational order in a two-dimensional solid. In 1968, Mermin proved that despite the absence of long range translational order. Two-dimensional solids can still exhibit a different kind of long range bond orientation. During the last decade, fascinating theori...
متن کاملDesign and simulation of a pressure sensor based on a two dimensional photonic crystal slab of PbMoO4
In this paper the design and three dimensions (3D) simulation of a photonic crystal (PC) pressure sensor is presented. The device is based on a 2D PC slab of PbMoO4. The simulations are based on finite element method (FEM) and finite-difference time-domain (FDTD) method and are done using CST STUDIO SUITE software. The sensitivity of the proposed sensor is calculated by considering the deformat...
متن کاملExperimental Study and Three-Dimensional Numerical Flow Simulation in a Centrifugal Pump when Handling Viscous Fluids
In this paper the centrifugal pump performances are tested when handling water and viscous oils as Newtonian fluids. Also, this paper shows a numerical simulation of the three-dimensional fluid flow inside a centrifugal pump. For these numerical simulations the SIMPLEC algorithm is used for solving governing equations of incompressible viscous/turbulent flows through the pump. The k-ε turbulenc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasound in medicine & biology
دوره 34 7 شماره
صفحات -
تاریخ انتشار 2008