Elastic Photon Scattering and Normalization of In Vivo XRF Analyses of Pb in Bone

نویسندگان

  • D. A. Bradley
  • Lynn Kissel
  • R. H. Pratt
چکیده

In recent years in vivo XRF has been found to be an effective aid to occupational health in the monitoring of concentrations of Pb in bone. One popular technique is to site an appropriate source-detector arrangement proximal to the tibial bone. Particularly popular has been use of a relatively high activity point or annular source of Cd mounted on the front of a thin-window HPGe detector. XRF excited by source photons at 88.0keV are detected in the backwards direction, the K XRF peaks appearing on the trailing edge of a broad Compton peak, due to the bone and tissue mass, followed by an elastically scattered peak assumed to be due to the Ca and P in bone. The elastically scattered peak is used to normalize the detected K shell fluorescence in order to obtain an analysis in terms of micrograms of Pb per g of bone mineral. In the following simulation of elastic scattering from compact bone (ICRU-37 8-element composition) and soft tissue (ICRU-44 9element composition) with Pb (at 0, 10, 20, 50, 100, 200, 500 and 100 ppm by mass), we have examined the extent to which Pb concentrations can lead to inaccuracies in the normalization procedure. Our results show that at 10 and 165 degrees, for energies 11000 keV, the contribution from Pb to the total elastic scattering sharply increases with increasing photon energy above the K-photoeffect threshold (above about 100 keV), and Pb is more important to the total elastic cross section at 165 degrees than at 10 degrees. For 165-degree scattering and concentrations of 100 ppm, Pb contributes to the total elastic scattering at 88 keV at 0.03% for soft tissue, and 0.01% for bone; at the 1% level in soft tissue by about 150 keV, and in bone by about 250 keV; at the 5% level in soft tissue by about 280 keV, and in bone by about 650 keV. *Work performed under the auspices of the USDOE by Lawrence Livermore National Laboratory under contract No. W-7405-Eng-48. Introduction: In recent years increasing interest has been shown in the application of K-shell x-ray fluorescence (XRF) techniques for the in vivo determination of lead in bone (see for instance O'Meara and Chettle, presented at this Meeting). Standardisation is obtained through use of phantoms containing known loadings of Pb. One of the most developed of techniques involves use of a backwards angle scattering geometry in which the various Pb K-shell fluorescence peaks appear on the trailing edge of a dominating Compton peak. The Compton and Rayleigh scattering peaks which are apparent are due to scattering from tissues within the field of view, the elastic scattering peak being a sensitive reflection of the Ca and P composition of bone. Recognition of this has lead to use of the elastic scattering peak in normalisation procedures, the intention being to take account of differences between phantoms and subjects and geometry dependent effects which include subject movement. For tibial bone Pb measurements using a Cd source Somervaille et al (1985, 1989) have estimated associated uncertainties of the order of 1to 2%. Such uncertainty analysis does not take into account the possible effect upon peak intensity of relatively high loadings of Pb in bone, the results of which may depend upon Pb concentration variations. In the present study use has been made of accurate predictions for elastic scattering cross-sections in assessing the possible magnitude of Pb-loading effects. Methods: In the present study we have looked at scattering from soft tissues (ICRU-44 9-element composition) with Pb (at 0. 10, 20, 50, 100, 200, 500 and 1000ppm by mass) at scattering angles of 10° and 165°, for photon energies 1 1000keV. Use has been made of modified relativistic scattering cross-sections in combination with angle dependent anomalous scattering factors (MSASF) as the basis of the elastic scattering calculations. These form factor approach has been compared with S-matrix predictions at selected energies in the range 11000keV. The MFASF predictions produced reasonably consistent results over the chosen photon energy range, errors being significantly smaller than 30% below 100keV, of the order of 30% for large angles for photon energies of 100 200 keV, growing to a factor of 2 at higher energies. Results: Plots have been made of the percentage relative difference which are obtained when comparison is made between cross-sections from soft tissue with (CS2) and without Pb

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PARAMETER STUDIES FOR AN OPTIMIZED XRF-DETERMINATION OF Pb IN BONE

One of the main threats to human health from heavy metals is associated with the exposure to lead (Pb). In vivo X-ray fluorescence analysis (XRF) of human bone is a widely used technique to determine the total Pb body burden. The intention of this work was to study the feasibility of in vivo L-shell XRF measurements of Pb in bone using X-ray tubes as excitation sources. Parameter studies using ...

متن کامل

Monte Carlo Modeling of Dual and Triple Photon Energy Absorptiometry Technique

Introduction: Osteoporosis is a bone disease in which there is a reduction in the amount of bone mineral content leading to an increase in the risk of bone fractures. The affected individuals not only have to go through lots of pain and suffering but this disease also results in high economic costs to the society due to a large number of fractures.  A timely and accurate diagnosis of this disea...

متن کامل

XRF-measured bone lead (Pb) as a biomarker for Pb exposure and toxicity among children diagnosed with Pb poisoning.

Childhood lead (Pb) poisoning remains a global issue, especially in industrial areas. In this study, 115 children with average age 5.7 years were recruited as either patient diagnosed with Pb poisoning or controls at Xinhua Hospital in China. The subjects' bone Pb was measured with a K-shell X-ray fluorescence (KXRF) and a portable X-ray fluorescence (XRF) system. A significant correlation betw...

متن کامل

- th / 0 11 10 20 v 2 1 5 Fe b 20 02 LA - UR - 01 - 6133 Discerning the neutron density distribution of 208 Pb from nucleon elastic scattering

We seek a measure of the neutron density of Pb from analyses of intermediate energy nucleon elastic scattering. The pertinent model for such analyses is based on coordinate space nonlocal optical potentials obtained from model nuclear ground state densities. Those potentials give predictions of integral observables and of angular distributions which show sensitivity to the neutron density. When...

متن کامل

Evaluation of Breast Cancer Radiation Therapy Techniques in Outfield Organs of Rando Phantom with Thermoluminescence Dosimeter

Background: Given the importance of scattered and low doses in secondary cancer caused by radiation treatment, the point dose of critical organs, which were not subjected to radiation treatment in breast cancer radiotherapy, was measured.Objective: The purpose of this study is to evaluate the peripheral dose in two techniques of breast cancer radiotherapy with two energies. Methods: Eight diff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999