How much change is true change? The minimum detectable change of the Berg Balance Scale in elderly people.

نویسندگان

  • Declan Donoghue
  • Emma K Stokes
چکیده

OBJECTIVE To determine the minimum detectable change at 95% confidence for the Berg Balance Scale in a group of elderly people, undergoing physiotherapy rehabilitation. DESIGN Multi-centre, test-retest design. SUBJECTS Cross-sectional sample of convenience of people over 65 years (n = 118) without a previous history of stroke, Parkinson's disease or recent hip arthroplasty. RATERS: Physiotherapists working with elderly people, drawn from the Physiotherapy Research into Older People group, ranging in experience from newly qualified to 39 years qualified. METHODS Each participant was assessed using the Berg Balance Scale and again within 48 hours by the same physiotherapist. The minimum detectable change at 95% was established. RESULTS A change of 4 points is needed to be 95% confident that true change has occurred if a patient scores within 45-56 initially, 5 points if they score within 35-44, 7 points if they score within 25-34 and, finally, 5 points if their initial score is within 0-24 on the Berg Balance Scale. CONCLUSION A clinician with a working knowledge of these minimum detectable change values can be up to 95% confident that a true change or not a true change in a patients' functional balance has occurred and can therefore alter their interventions accordingly to ensure quality, focused rehabilitation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Test-retest reliability and minimal detectable change for center of pressure measures of postural stability in elderly subjects

  Abstract   Background: Postural instability has been identified as a potential precursor of   falls in elderly subjects. Postural stability in quiet stance is commonly assessed with   center of pressure (COP) measures. The purpose of this study was to determine testretest reliability and minimal detectable change (MDC) for the center of pressure   (COP) measures in the elderly subjects.   Met...

متن کامل

Prediction of Risk of Falling among Institutionalized Elderly People in Iran

Aging declines abilities and leads to increased risk of falling and subsequently poorer quality of life. The objective of this study was to identify a proper assessment for risk of falling among institutionalized elderly. In order to accomplish this aim, two functional assessment methods, Berg Scale and Tinetti Scale, were used and the validity indices of these methods were calculated. Prospect...

متن کامل

پایایی آزمون-بازآزمون، روایی سازه و همخوانی درونی نسخه فارسی‌شده آزمون «مقیاس تعادل پیشرفته فولرتون» در سالمندان ایرانی مقیم جامعه

Objectives: This study was performed to evaluate convergent validity, test-retest reliability and internal consistency of the Persian translation of the Fullerton advanced balance (FAB) for use in Iranian community- dwelling older adults and improve the quality of their functional balance assessment. Methods & Materials: The original scale was translated with forward-backward protoco...

متن کامل

Effectiveness of Treadmill Training on Balance Control in Elderly People: A Randomized Controlled Clinical Trial

Physical exercise would improve postural stability, which is an essential factor in preventing accidental fall among the elderly population. The aim of this study is to examine the effectiveness of treadmill walking on balance improvement among the elderly people. A total of 30 community dwelling older adults with a Berg Balance Scale score of 36-48 and the ability to walk without aid were cons...

متن کامل

The evaluation of minimum detectable phantom thickness change using a scanning liquid filled ion chamber EPID dose response

 ABSTRACTBackground: Although Electronic Portal imaging Devices (EPIDs) have originally developed for positioning verification, they can also be used for dosimetric purposes. In the current work, the dose response of minimum detectable thickness of a Scanning Liquid filled Ion Chamber EPID, SLIC-EPID, and the variation of transmitted dose with the shift of inhomogeneity inside of phantom was al...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of rehabilitation medicine

دوره 41 5  شماره 

صفحات  -

تاریخ انتشار 2009