The impact of CyberKnife's prescription isodose percentage on intracranial target planning
نویسندگان
چکیده
To the Editor: Recently, a detailed comparative study regarding intracranial Gamma Knife (GK) vs. CyberKnife (CK) intracranial dosimetry has been published by your Journal.(1) In a group of 15 patients with 26 brain metastases, we showed that CK produced more homogeneous and conformal plans, while the GK plans had sharper peripheral dose falloff in most cases. In the CK plans, by convention, the applied range of prescription isodose percentage (PIP) was 77%–92%, with a median value of 86%. Intrigued by the results, we hypothesized that lowering the PIP in CK planning would improve peripheral dose falloff, without compromising the excellent dosimetric conformality which had previously been achieved. Secondarily, it was expected that, as PIP decreased, the stereotactic radiosurgical (SRS) plans would become less homogeneous as maximum dose within the target increased. We thank you for the opportunity to share with you the additional results that were generated from this investigation. Parts of the methods and materials have been previously described.(1) We compared the relative dosimetric merit of various prescription isodose levels in CK’s MultiPlan (Accuray Inc, Sunnyvale, CA). The same 15-patient series was used for dosimetric planning. For each tumor, the PIP was varied at three levels averaging approximately 50, 65, and 85% (CK50, CK65 and CK85; Table 1). The homogeneity (HI) and gradient (GI) indices, modified conformity index (mCI, the ratio of the prescription isodose volume to the tumor volume receiving at least the prescription dose), and an MPS-defined quantity called “new CI” (nCI, the ratio of mCI to target coverage, also the inverse of van’t Riet’s Conformation Number) were computed. For peripheral dose falloff, GI50 was calculated as the ratio of the volume enclosed by the isodose at 50% of the prescription dose level to the volume enclosed by the original prescription isodose. GI25, GI40, GI60, and GI80 were calculated in a similar manner. Statistical analyses were performed using analysis of variance (ANOVA) and nonparametric Kruskal-Wallis tests. We found that the mean tumor volume was 4.4 cm3; a median dose of 18 Gy was prescribed. For CK50, CK65, and CK85 series, the coverage was maintained at 96%–100% in all cases. Optimized plans in each scenario across various PIPs were computed, and dosimetric constraints of critical organ structures were all met. Minimum, average, maximum doses, HI, nCI, GI25, GI50, and MU were reported (Table 2). Comparing across the CK50, CK65, and CK85 series, the median mCIs were: 1.48, 1.36, and 1.52, p =.086, respectively. The remaining gradient indices were: GI40 (5.8, 6.9, and 7.6, p = 0.0008); for GI60 (2.8, 3.4, and 3.8), GI80 (1.6, 1.9, and 2.2), and GI90 (1.3, 1.4, and 1.6), p < 0.00001 in all cases. In our study, as expected, the selection of a PIP had a statistically significant impact on HI, mean, and maximum doses. By both mCI and nCI, CK65 produced the most conformal plans which nearly reached statistical significance. Importantly, CK50 had significantly sharpest dose falloff at all gradient index levels, with the exception of GI25. However, dosimetric plans prescribing to CK50 required significantly longer treatment times by MU estimation. In current clinical practices, deciding a prescription isodose level in CK varies by individual plan and preference, and clearly no consensus exists. The CK is a relatively new modality for SRS, which is stereotactically capable for extracranial indications, as well. For GK and linacbased intracranial SRS, it is common to prescribe to 40%–60% and 80%–95% of PIP, respectively. It is then customarily believed that the PIPs of CK should fall between those of the GK and linac-based SRS plans, as CK shares features of both. For CK dosimetric planning, some JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 15, NUMBER 5, 2014
منابع مشابه
A new variable for SRS plan quality evaluation based on normal tissue sparing: the effect of prescription isodose levels.
OBJECTIVE A new dosimetric variable, dose-dropping speed (DDS), was proposed and used to evaluate normal tissue sparing among stereotactic radiosurgery (SRS) plans with different prescription isodose lines. METHODS 40 plans were generated for 8 intracranial SRS cases, prescribing to isodose levels (IDLs) ranging from 50% to 90% in 10% increments. Whilst maintaining similar coverage and confor...
متن کاملSU-E-T-453: Optimization of Dose Gradient for Gamma Knife Radiosurgery.
PURPOSE The goals of stereotactic radiosurgery (SRS) are the ablation of target tissue and sparing of critical normal tissue. We develop tools to aid in the selection of collimation and prescription (Rx) isodose line to optimize the dose gradient for single isocenter intracranial stereotactic radiosurgery (SRS) with GammaKnife 4C utilizing the updated physics data in GammaPlan v10.1. METHODS ...
متن کاملEffect of the normalized prescription isodose line on the magnitude of Monte Carlo vs. pencil beam target dose differences for lung stereotactic body radiotherapy
In lung stereotactic body radiotherapy (SBRT) cases, the pencil beam (PB) dose calculation algorithm is known to overestimate target dose as compared to the more accurate Monte Carlo (MC) algorithm. We investigated whether changing the normalized prescription isodose line affected the magnitude of MC vs. PB target dose differences. Forty-eight patient plans and twenty virtual-tumor phantom plan...
متن کاملDosimetric comparison of volumetric modulated arc therapy (VMAT), step and shoot and sliding window IMRT for prostate cancer Introduction: The goal of delivering higher uniform doses to the planning
ID: 17554 Title: Dosimetric comparison of volumetric modulated arc therapy (VMAT), step and shoot and sliding window IMRT for prostate cancer 1 : Baltas D, Kolotas C, Geramani K, et al. A conformal index (COIN) to evaluate implant quality and dose specification in brachytherapy. Int J Radiat Oncol Biol Phys 40, 515-524 (1998). 2 : van’t Riet A, Mak AC, Moerland MA, et al. A conformation number ...
متن کاملDosimetric comparison of various optimization techniques for high dose rate brachytherapy of interstitial cervix implants
HDR brachytherapy treatment planning often involves optimization methods to calculate the dwell times and dwell positions of the radioactive source along specified afterloading catheters. The purpose of this study is to compare the dose distribution obtained with geometric optimization (GO) and volume optimization (VO) combined with isodose reshaping. This is a retrospective study of 10 cervix ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -