It has recently been shown that 'sub-atomic' contrast can be observed during NC-AFM imaging of the Si(111)-7×7 substrate with a passivated tip, resulting in triangular shaped atoms [Sweetman et al. Nano Lett. 2014, 14, 2265]. The symmetry of the features, and the well-established nature of the dangling bond structure of the silicon adatom means that in this instance the contrast cannot arise from the orbital structure of the atoms, and it was suggested by simple symmetry arguments that the contrast could only arise from the backbonding symmetry of the surface adatoms. However, no modelling of the system has been performed in order to understand the precise origin of the contrast. In this paper we provide a detailed explanation for 'sub-atomic' contrast observed on Si(111)-7×7 using a simple model based on Lennard-Jones potentials, coupled with a flexible tip, as proposed by Hapala et al. [Phys. Rev. B 2014, 90, 085421] in the context of interpreting sub-molecular contrast. Our results show a striking similarity to experimental results, and demonstrate how 'sub-atomic' contrast can arise from a flexible tip exploring an asymmetric potential created due to the positioning of the surrounding surface atoms.
منابع مشابه
Influences of H on the Adsorption of a Single Ag Atom on Si(111)-7 × 7 Surface
The adsorption of a single Ag atom on both clear Si(111)-7 × 7 and 19 hydrogen terminated Si(111)-7 × 7 (hereafter referred as 19H-Si(111)-7 × 7) surfaces has been investigated using first-principles calculations. The results indicated that the pre-adsorbed H on Si surface altered the surface electronic properties of Si and influenced the adsorption properties of Ag atom on the H terminated Si ...
متن کاملKCl ultra-thin films with polar and non-polar surfaces grown on Si(111)7 × 7
The growth of ultra-thin KCl films on the Si(111)7 × 7 reconstructed surface has been investigated as a function of KCl coverage and substrate temperature. The structure and morphology of the films were characterized by means of scanning tunneling microscopy (STM) under ultra-high vacuum (UHV) conditions. Detailed analysis of the atomically resolved STM images of islands grown at room and high ...
متن کاملImaging silicon by atomic force microscopy with crystallographically oriented tips
The images obtained by atomic force microscopy (AFM) originate from a convolution of atomic tip and sample states. Since the vertical resolution of AFM is approaching the picometer level, the atomic and subatomic structure of the tip is becoming increasingly important. Here, we demonstrate the preparation of crystallographically oriented AFM tips by breaking a silicon wafer along its preferenti...
متن کاملAtomic-scale X-ray structural analysis of self-assembled monolayers on Silicon
Two related self-assembled monolayers (SAMs), 4-bromostyrene (BrSty) and 4-bromophenylacetylene (BPA), are photochemically grown from solution on to the monohydride-terminated Si(111) surface. The atomic-scale structures of the resulting SAMs are examined by X-ray standing waves (XSW), X-ray reflectivity (XRR), X-ray fluorescence, atomic-force microscopy (AFM), X-ray photoelectron spectroscopy ...
متن کاملIdentifying tips for intramolecular NC-AFM imaging via in situ fingerprinting
A practical experimental strategy is proposed that could potentially enable greater control of the tip apex in non-contact atomic force microscopy experiments. It is based on a preparation of a structure of interest alongside a reference surface reconstruction on the same sample. Our proposed strategy is as follows. Spectroscopy measurements are first performed on the reference surface to ident...