The Performance of CRTNT Fluorescence Light Detector for Sub-Ee

نویسندگان

  • Y. Bai
  • B. Zhang
  • Z. Cao
چکیده

Cosmic Ray Tau Neutrino Telescopes (CRTNT) using for sub-EeV cosmic ray measurement is discussed. Performances of a stereoscope configuration of a tower of those telescopes plus two side-triggers are studied by using a detailed detector simulation driven by Corsika. Detector aperture as a function of shower energy above 10 eV is calculated. Event rate of about 20k per year for the second knee measurement is estimated. Event rate for cross calibration with detectors working on higher energy range is also estimated. Different configurations of the detectors are tried for optimization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Performance of CRTNT Fluorescence Light Detector for Sub-EeV Cosmic Ray Observation

Cosmic Ray Tau Neutrino Telescopes (CRTNT) using for sub-EeV cosmic ray measurement is discussed. Performances of a stereoscope configuration of a tower of those telescopes plus two side-triggers are studied by using a detailed detector simulation driven by Corsika. Detector aperture as a function of shower energy above 10 eV is calculated. Event rate of about 20k per year for the second knee m...

متن کامل

Simulation of Cosmic Ray Tau Neutrino Telescope (CRTNT) Experiment

A τ lepton can be produced in a charged current interaction by cosmic ray tau neutrino with material inside a mountain. If it escapes from the mountain, it will decay and initiate a shower in the air, which can be detected by an air shower fluorescence/Cherenkov light detector. Designed according to such a principle, the Cosmic Ray Tau Neutrino Telescope (CRTNT) experiment, located at the footh...

متن کامل

Organic matter from biofilter nitrification by high performance size exclusion chromatography and fluorescence excitation-emission matrix

A combination of high performance size exclusion chromatography with organic carbon detector and ultraviolet detector coupled with peak-fitting technique and fluorescence excitation-emission matrix spectrometry applied fluorescence regional integration method was conducted to determine the characteristics of organic matter during nitrification. The batch scale of bionet nitrification without or...

متن کامل

Normal Heptane Reforming of Promoted Platinum Composite Catalysts: Preparation, Characterization and Catalytic Performance

Pt/Zr(x)-HMS/HZSM-5 catalysts with different ratios of Silicium/Zirconium (denoted as x) were studied for normal heptane reforming at 350-450 °C temperature range. For this purpose, the properties of the catalysts such as X-ray diffraction, X-ray fluorescence, Fourier-transform infrared spectroscopy, Ultraviolet–visible diffuse reflectance spectroscopy, NH3-temperature pro...

متن کامل

Effect of gibberellic acid on some fluorescence and chlorophyll characteristics of Cyclamen persicum Mill. seedlings under different light regimes

The use of growth regulators and light quality change are two methods to improve plant performance. Therefore, a factorial experiment was conducted in a completely randomized design. Factors included three light modes (greenhouse light (control) and LED combination light of white: red: blue as 70: 10: 20 and 40: 40: 20 ratios) and gibberellic acid in four concentrations (0, 20, 40 and 60 mg/l)....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006