Ease of intubation with the Parker Flex-Tip or a standard Mallinckrodt endotracheal tube using a video laryngoscope (GlideScope).
نویسندگان
چکیده
Two endotracheal tubes (ETTs) are available for use in operative suites for intubation: the Parker Flex-Tip (PFT, Parker Medical) and the standard Mallinckrodt (Covidien). To the authors' knowledge, no study has compared these 2 ETTs with each other when the anesthesia provider uses the GlideScope video laryngoscope (Verathon) for intubation. The purpose of the study was to determine if there are differences related to ease of intubation reported by anesthesia providers who use the PFT tube compared with the standard tube while using the GlideScope. The study was a randomized block intervention design. The sample consisted of 58 observed intubations in an operating room setting. Data analysis was completed with a 2-factor analysis of covariance using 2 covariates. The PFT tube in suboptimal conditions demonstrated a significantly greater ease of intubation, as measured by decreased time for ETT insertion and greater ease of ETT insertion score. The number of redirections at the glottis to intubate the trachea once the glottis was visualized was not statistically different. Based on the findings from this study, anesthesia providers may want to consider the use of the PFT tube when using the GlideScope to promote ease of intubation.
منابع مشابه
Methods to Improve Success With the GlideScope Video Laryngoscope.
Occasionally intubation of patients is difficult using a video laryngoscope (GlideScope, Verathon Medical) because of an inability to guide the endotracheal tube to the glottis or pass the tube into the trachea despite an adequate view of the glottis. We examined methods to improve success when this difficulty occurs. A literature search revealed 253 potential sources, with 25 meeting search cr...
متن کاملA Randomized Comparison of a Parker Endotracheal Tube and a Standard Tube Oriented 90° Counterclockwise
Purpose: During oral fiberoptic intubation, advancement of an endotracheal tube (ETT) into the trachea is occasionally impeded by laryngeal structures. The curved flex tip Parker ETT has been shown to improve the likelihood of successful advancement as opposed to a standard ETT that is advanced in neutral orientation. However, a Parker tube has not been compared to a standard ETT oriented 90 ̊ c...
متن کاملLocal anaesthesia for ‘awake intubation’ using the TruView PCD video laryngoscope.
Editor, I would like to present a method of local anaesthesia for ‘awake intubation’, i.e. intubation in a conscious patient under local anaesthesia and sedation using the Truview PCD laryngoscope (Truphatek, Israel), for cases of anticipated difficult intubation. The use of video laryngoscopes for awake intubation has been described in the literature as a good alternative to fibreoptic intubat...
متن کاملEvaluation of intra ocular pressure and hemodynamic change following intubation with Maccoy, Macintosh and Video laryngoscope
Background & Objective: The induction of anesthesia, laryngoscopy and endotracheal intubation can be associated with adverse hemodynamic response and increased intraocular pressure. The aim of this study was to evaluate intraocular pressure and hemodynamic changes after laryngoscopy and endotracheal intubation with three methods of laryngoscopy (Macintosh, Maccoy and Video laryngoscope).Materia...
متن کاملمقایسه میزان موفقیت لوله گذاری تراشه بعد از آموزش با دو روش گلایدسکوپ و لارنگوسکوپ
Background: Tracheal intubation is one of the most essential skills employed by all healthcare providers, nevertheless novice intubators turn out to be less successful when they initially perform the intubation. Video- laryngoscopes (GlideScopes) are novel instruments able to increase the success rate of tracheal intubation training. The aim of this study was to compare the success rate of trac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AANA journal
دوره 80 5 شماره
صفحات -
تاریخ انتشار 2012