Measurements of exit dose profiles in 60Co beams with a conventional portal film system.

نویسندگان

  • M Stasi
  • V Casanova Borca
  • C Fiorino
چکیده

An important step in the verification of the reliability of portal films as in vivo dosemeters is the evaluation of the agreement between exit dose profiles and optical density profiles measured on the portal film. To test the possibilities of a conventional portal film system in 60Co beams suitable for head and neck irradiation, we verified the agreement between relative exit doses (measured by ionization chamber) and relative optical densities, on cubic homogeneous phantoms, on an homogeneous "step" phantom and on a cubic phantom including air and aluminium inhomogeneities. The optical density profiles were corrected with the appropriate sensitometric curves. For an homogeneous phantom 10.8 cm thick and with the film in contact with the phantom, the agreement was found to be excellent with a mean deviation of 0.8% and a maximum deviation of 1.5%. The agreement was worse when the air gap between the exit surface of the phantom and the portal film was increased (with an air gap equal to 15 cm the maximum deviation was 4%), and when the thickness of the phantom was increased (for a thickness of 14.4 cm the maximum deviation was 3.1%). The agreement was found to be acceptable for the "step" phantom too, with a mean deviation around 1% and a maximum deviation within 2% (air gap equal to zero). When air and aluminium inhomogeneities were incorporated into the phantom a maximum deviation of 6% and a mean deviation less than 3% were found. Furthermore, the relative optical density profiles show an underestimate of measured off-axis exit dose values under a high density inhomogeneity and a small overestimate under a low density inhomogeneity. Results suggest the possibility of using conventional portal films for exit relative dosimetry in head and neck irradiation with 60Co beams if the air gap is kept as small as possible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric comparison between XR-RV3 and EBT2 radiochromic film in megavoltage photon beams

Background:  Radiochromic film is used for radiation dose measurement, XR-RV3 is used in fluoroscopy and EBT2 film in radiation therapy. The aim was to determine if the dosimetric properties of these two films are comparable in megavolt photon beams. Materials and Methods: Comparison measurements included: calibration curves, heterogeneous phantom dose profiles, and nasopharynx dose distributio...

متن کامل

Pretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)

Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...

متن کامل

Experimental Evaluation of Depth Dose by Exit Surface Diode Dosimeters for Off-Axis Wedged Fields in Radiation Therapy

Introduction Evaluation of the delivered dose of externally wedged photon beams by external diode dosimeters during the treatment process requires the estimation of exit surface dose correction factors in various wedge angles and field sizes. Materials and Methods A system of absorbed dose evaluation, using p-type diode dosimeters placed on the exit surface of a phantom, was characterized for e...

متن کامل

Evaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation

Introduction: GafChromic EBT films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (TPSs). Their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. This study was designed to evaluate the dosimetric parameters of...

متن کامل

Evaluation of Three-dimensional Treatment Planning System (TPS) performance in dose calculation of virtual wedged fields using film dosimetry

Introduction: Nowadays radiotherapy plays an important role in cancer treatment. Different radiotherapy techniques improvement emphasizes on using of the precise ، appropriate and useful algorithms. one of these techniques are wedged which is used in radiotherapy to compensate missing tissues and create a uniform dose distribution in tissues. The Siemens Artiste linear accelera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of radiology

دوره 70 840  شماره 

صفحات  -

تاریخ انتشار 1997