Temporal modulation transfer functions in cochlear implantees using a method that limits overall loudness cues
نویسندگان
چکیده
Temporal modulation transfer functions (TMTFs) were measured for six users of cochlear implants, using different carrier rates and levels. Unlike most previous studies investigating modulation detection, the experimental design limited potential effects of overall loudness cues. Psychometric functions (percent correct discrimination of modulated from unmodulated stimuli versus modulation depth) were obtained. For each modulation depth, each modulated stimulus was loudness balanced to the unmodulated reference stimulus, and level jitter was applied in the discrimination task. The loudness-balance data showed that the modulated stimuli were louder than the unmodulated reference stimuli with the same average current, thus confirming the need to limit loudness cues when measuring modulation detection. TMTFs measured in this way had a low-pass characteristic, with a cut-off frequency (at comfortably loud levels) similar to that for normal-hearing listeners. A reduction in level caused degradation in modulation detection efficiency and a lower-cut-off frequency (i.e. poorer temporal resolution). An increase in carrier rate also led to a degradation in modulation detection efficiency, but only at lower levels or higher modulation frequencies. When detection thresholds were expressed as a proportion of dynamic range, there was no effect of carrier rate for the lowest modulation frequency (50 Hz) at either level.
منابع مشابه
Spectro-temporal cues enhance modulation sensitivity in cochlear implant users.
Although speech understanding is highly variable amongst cochlear implants (CIs) subjects, the remarkably high speech recognition performance of many CI users is unexpected and not well understood. Numerous factors, including neural health and degradation of the spectral information in the speech signal of CIs, likely contribute to speech understanding. We studied the ability to use spectro-tem...
متن کاملLoudness summation for two channels of stimulation in cochlear implants: effects of spatial and temporal separation.
An experiment with four implantees with the Mini System 22 device was undertaken to measure the loudness summation across two channels of stimulation, with stimuli in which the current pulses were delivered alternately to each channel. The effects of varying spatial separation, temporal separation, and extent of stimulation were investigated. It was found that the absolute amount of summation v...
متن کاملLoudness of dynamic stimuli in acoustic and electric hearing.
Traditional loudness models have been based on the average energy and the critical band analysis of steady-state sounds. However, most environmental sounds, including speech, are dynamic stimuli, in which the average level [e.g., the root-mean-square (rms) level] does not account for the large temporal fluctuations. The question addressed here was whether two stimuli of the same rms level but d...
متن کاملTemporal integration of loudness in listeners with hearing losses of primarily cochlear origin.
To investigate how hearing loss of primarily cochlear origin affects the loudness of brief tones, loudness matches between 5- and 200-ms tones were obtained as a function of level for 15 listeners with cochlear impairments and for seven age-matched controls. Three frequencies, usually 0.5, 1, and 4 kHz, were tested in each listener using a two-interval, two--alternative forced--choice (2I, 2AFC...
متن کاملBasilar-membrane Activity and Loudness
Buus and Florentine (ISP meeting 2001) presented evidence that basilar-membrane velocity growth functions are proportional to the square root of loudness functions derived from temporal and spectral integration. Although it is not possible to directly measure basilarmembrane activity in humans, it is likely that tone-burst otoacoustic emission input-output functions, at least at low and moderat...
متن کامل