Differences in dynamic susceptibility contrast MR perfusion maps generated by different methods implemented in commercial software.

نویسندگان

  • Laura Orsingher
  • Silvia Piccinini
  • Girolamo Crisi
چکیده

PURPOSE There are several potential sources of difference that can influence the reproducibility of magnetic resonance (MR) perfusion values. We aimed to investigate the reproducibility and variability of dynamic susceptibility contrast (DSC) MR imaging (MRI) parameters obtained from identical source data by using 2 commercially available software applications with different postprocessing algorithms. METHODS AND MATERIALS We retrospectively evaluated DSC-MRI data sets of 24 consecutive patients with glioblastoma multiforme. Perfusion data were postprocessed with 2 commercial software packages, NordicICE (NordicNeuroLab, Bergen, Norway) and GE Brainstat (GE Healthcare, Milwaukee, Wis), each of which offers the possibility of different algorithms. We focused the comparison on their main analysis issues, that is, the gamma-variate fitting function (GVF) and the arterial input function (AIF). Two regions of interest were placed on maps of perfusion parameters (cerebral blood volume [CBV], cerebral blood flow [CBF], mean transit time [MTT]): one around tumor hot spot and one in the contralateral normal brain. A one-way repeated-measures analysis of variance was conducted to determine whether there was a significant difference in the calculated MTT, CBV, and CBF values. RESULTS As regards NordicICE software application, the use of AIF is significant (P = 0.048) but not the use of GVF (P = 0.803) for CBV values. Additionally, in GE, the calculation method discloses a statistical effect on data. Comparing similar GE-NordicICE algorithms, both method (P = 0.005) and software (P < 0.0001) have a statistical effect in the difference. Leakage-corrected and uncorrected normalized CBV (nCBV) values are statistically equal. No statistical differences have been found in nMTT values when directly calculated. Values of nCBF are affected by the use of GVF. CONCLUSION The use of a different software application determines different results, even if the algorithms seem to be the same. The introduction of AIF in the data postprocessing determines a higher estimates variability that can make interhospital and intrahospital examinations not completely comparable. A simpler approach based on raw curve analysis produces more stable results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging

Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...

متن کامل

An Efficient Framework for Accurate Arterial Input Selection in DSC-MRI of Glioma Brain Tumors

Introduction: Automatic arterial input function (AIF) selection has an essential role in quantification of cerebral perfusion parameters. The purpose of this study is to develop an optimal automatic method for AIF determination in dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) of glioma brain tumors by using a new preprocessing method.Material and Methods: For this study, ...

متن کامل

Quantification of blood flow in brain tumors: comparison of arterial spin labeling and dynamic susceptibility-weighted contrast-enhanced MR imaging.

PURPOSE To implement an arterial spin labeling technique that is feasible in routine examinations and to test the method and compare it with dynamic susceptibility-weighted contrast material-enhanced magnetic resonance (MR) imaging for evaluation of tumor blood flow (TBF) in patients with brain tumors. MATERIALS AND METHODS Thirty-six patients with histologically proven brain tumors were exam...

متن کامل

A standardized method of generating time-to-peak perfusion maps in dynamic-susceptibility contrast-enhanced MR imaging.

BACKGROUND AND PURPOSE Perfusion MR imaging, performed as dynamic-susceptibility contrast-enhanced MR imaging, is sensitive to hemodynamic risks for patients with cerebrovascular disease. We sought to define a quantitative parameter for perfusion MR imaging, which shows brain areas at hemodynamic risk and enables direct comparison of different perfusion MR imaging examinations. METHODS A new ...

متن کامل

Measurement of cerebral blood flow in chronic carotid occlusive disease: comparison of dynamic susceptibility contrast perfusion MR imaging with positron emission tomography.

BACKGROUND AND PURPOSE Our purpose was to evaluate the accuracy of cerebral blood flow (CBF) measurements obtained by using dynamic susceptibility contrast-enhanced MR imaging, including the influence of arterial input function (AIF) selection, compared with those obtained by using [(15)O]-H(2)O positron emission tomography (PET) for patients with chronic carotid occlusion. METHODS MR images ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of computer assisted tomography

دوره 38 5  شماره 

صفحات  -

تاریخ انتشار 2014