Effect of specimen type on free immunoglobulin light chains analysis on the Roche Diagnostics cobas 8000 analyzer
نویسندگان
چکیده
The measurement of free immunoglobulin light chains is typically performed on serum; however, the use of alternative specimen types has potential benefits. Using the Freelite™ kappa and lambda free light chains assay on a Roche Diagnostics cobas 8000 c502 analyzer, we compared three specimen types (serum, EDTA-plasma and lithium heparin plasma separator gel-plasma) on 100 patients. Using Deming regression and eliminating outliers (limiting data to light chain concentrations below 400 mg/L), the three specimen types showed comparable results for kappa light chain concentration, lambda light chain concentration, and kappa/lambda ratio with slopes close to 1.0 and y-intercepts close to zero. EDTA-plasma showed slightly more positive bias relative to serum than lithium heparin. Analysis using EDTA-plasma and lithium heparin plasma showed comparable linearity, precision, and temperature stability. A single sample showing hook effect (not in the comparison set) gave comparable results using either plasma specimen type. For the Freelite™ kappa and lambda free light chains assay, both EDTA-plasma or lithium heparin-plasma can serve as acceptable substitutes for serum, at least for the Roche cobas 8000 analyzer.
منابع مشابه
Fully automated detection of hepatitis C virus RNA in serum and whole-blood samples.
In this study, we established a fully automated molecular assay for qualitative detection of hepatitis C virus (HCV) in serum and whole-blood samples and compared it with conventional molecular assays, including manual HCV RNA extraction protocols. Whole-blood samples were collected from patients with and without chronic HCV infection in EDTA tubes and nucleic acid stabilization tubes (NASTs). ...
متن کاملتعیین اپی توپ های ناپیوسته زنجیره سبک ایمونوگلوبولین انسان توسط ایمونولوژی محاسبه ای
Background: Immunoglobulins are a group of proteins that have important role in defense against microorganisms. Immunoglobulins consist of heavy and light chains. In human, immunoglobulin light chain comprises of two isotypes: Kappa (K) and lambda (λ) based on amino acid differences in carboxylic end of their constant region. Marked changes in the K to λ ratio can happen in monocl...
متن کاملComparison of free κ and λ light chain immunoassays and total (bound and free) κ and λ light chain immunoassays.
Comparison of free κ and λ light chain immunoassays and total (bound and free) κ and λ light chain immunoassays To the editor: We read, with interest, the article by Dr. Zamora-Ortiz, et al. Poor performance of the total kappa/ lambda light chain quantification in the diagnosis and follow-up of patients with multiple myeloma on the comparison of the total serum light chain assay (sLC), SPE and ...
متن کاملComparative precision analysis of Precision-controls on automated chemistry analyzers
Background: Automated diagnostic equipments took over manual testing in last three decades, that allowed enhanced reproducibility, precision and accurateness of results; in addition to 24/7 availability of major lab testing profiles. Aim: In this regard, present study described comparative equipments’ precision assessment of conventional chemistry analyzer, Hirachi 912 with Cobas c501 on parame...
متن کاملInfluence of Iron Deficiency Anemia on Hemoglobin A1C Levels in Diabetic Individuals with Controlled Plasma Glucose Level
Introduction: Hemoglobin A1C (HbA1c) reflects patient’s glycemic status over the previous 3 months. Previous studies have reported that iron deficiency may elevate A1C concentrations, independent of glycemia. This study is aimed to analyze the effect of iron deficiency anemia on HbA1c levels in diabetic population having plasma glucose levels in control. Methods: Totally, 120 diabetic, iron-def...
متن کامل