SENSE-DTI at 3 T.
نویسندگان
چکیده
While holding vast potential, diffusion tensor imaging (DTI) with single-excitation protocols still faces serious challenges. Limited spatial resolution, susceptibility to magnetic field inhomogeneity, and low signal-to-noise ratio (SNR) may be considered the most prominent limitations. It is demonstrated that all of these shortcomings can be effectively mitigated by the transition to parallel imaging technology and high magnetic field strength. Using the sensitivity encoding (SENSE) technique at 3 T, brain DTI was performed in nine healthy volunteers. Despite enhanced field inhomogeneity, parallel acquisition permitted both controlling geometric distortions and enhancing spatial resolution up to 0.8 mm in-plane. Heightened SNR requirements were met in part by high base sensitivity at 3 T. A further significant increase in SNR efficiency was accomplished by SENSE acquisition, exploiting enhanced encoding speed for echo time reduction. Based on the resulting image data, high-resolution tensor mapping is demonstrated.
منابع مشابه
DTI at 7 and 3 T: systematic comparison of SNR and its influence on quantitative metrics.
Diffusion tensor imaging (DTI) and advanced related methods such as diffusion spectrum and kurtosis imaging are limited by low signal-to-noise ratio (SNR) at conventional field strengths. DTI at 7 T can provide increased SNR; however, B0 and B1 inhomogeneity and shorter T2⁎ still pose formidable challenges. The purpose of this study was to quantify and compare SNR at 7 and 3 T for different par...
متن کاملIn Vivo Human Brain Diffusion Tensor Imaging (DTI) at 3T and 7 T
Introduction: Higher B0 fields are expected to optimize fiber tracking and to increase the signal-to-noise ratio which should lead to higher spatial resolution of DTI [1,2]. However, at high fields B1 inhomogeneities are strong and result in sever distortions and signal voids in DTI. The B1 inhomogeneity results in ill-defined pulse angles that vary considerably over the probe volume. Parallel ...
متن کاملMethods to Improve Fiber Reconstruction at DTI-Based Tractography in the Area of Brain Tumor: Case Illustration and Literature Review
Background and Aim: DTI-based tractography could help us to visualize the spatial relation of fiber tracts to brain lesions. Several factors may interfere with the procedure of diffusion-based tractography, especially in brain tumors. The aim of the current study is to discuss several solutions to improve the procedure of fiber reconstruction adjacent or inside brain lesions. Illustrative cases...
متن کاملComparison of In Vivo and Ex Vivo Diffusion Tensor Imaging in Rhesus Macaques at Short and Long Diffusion Times
Diffusion tensor imaging (DTI) is widely used to non-invasively study neural tissue micro-structure. While DTI tractography of large nerve fibers is well accepted, visualization of smaller fibers and resolution of branching fibers is challenging. Sensitivity of DTI to diffusion anisotropy can be further enhanced using long diffusion time that can provide a more accurate representation of the ti...
متن کاملCost Analysis of Diffusion Tensor Imaging and MR Tractography of the Brain
Purpose: To determine the total direct costs (fixed and variable costs) of diffusion tensor imaging (DTI) and MR tractography reconstruction of the brain. Materials and Methods: The direct fixed and variable costs of DTI with MR tractography were determined prospectively with time and motion analysis in a 1.5-Tesla MR scanner using 15 encoding directions. Seventeen patients with seizure disorde...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 51 2 شماره
صفحات -
تاریخ انتشار 2004