Persistent acute inflammation at the implant-abutment interface.
نویسندگان
چکیده
The inflammatory response adjacent to implants has not been well-investigated and may influence peri-implant tissue levels. The purpose of this study was to assess, histomorphometrically, (1) the timing of abutment connection and (2) the influence of a microgap. Three implant designs were placed in the mandibles of dogs. Two-piece implants were placed at the alveolar crest and abutments connected either at initial surgery (non-submerged) or three months later (submerged). The third implant was one-piece. Adjacent interstitial tissues were analyzed. Both two-piece implants resulted in a peak of inflammatory cells approximately 0.50 mm coronal to the microgap and consisted primarily of neutrophilic polymorphonuclear leukocytes. For one-piece implants, no such peak was observed. Also, significantly greater bone loss was observed for both two-piece implants compared with one-piece implants. In summary, the absence of an implant-abutment interface (microgap) at the bone crest was associated with reduced peri-implant inflammatory cell accumulation and minimal bone loss.
منابع مشابه
Evaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro
Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...
متن کاملComparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study
Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...
متن کاملComparative Evaluation of Microgap at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study
Abstract Background and Aim : Microgap in the implant-abutment interface is one of the main challenges in the treatment of two-piece implants. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microgap at implant-abutment interface area under oblique cyclic loading in vitro. Methods and Materials In this in vitro study, 12 implant-abutment assemb...
متن کاملPeri-implant inflammation defined by the implant-abutment interface.
An implant-abutment interface at the alveolar bone crest is associated with sustained peri-implant inflammation; however, whether magnitude of inflammation is proportionally dependent upon interface position remains unknown. This study compared the distribution and density of inflammatory cells surrounding implants with a supracrestal, crestal, or subcrestal implant-abutment interface. All impl...
متن کاملMicroleakage at the abutment-implant interface of osseointegrated implants: a comparative study.
Microleakage can occur at the abutment-implant (A-I) interface in osseointegrated implants and may cause malodor and inflammation of peri-implant tissues. The degree of microleakage at the A-I interface of 5 implant systems was comparatively assessed at varying closing torques. Using colored tracing probes driven by a 2-atm pressure system, the interface microleakage of Brånemark, Sulzer Calcit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of dental research
دوره 82 3 شماره
صفحات -
تاریخ انتشار 2003