Is pre-operative anaemia a risk marker for in-hospital mortality and morbidity after valve replacement?

نویسندگان

  • Mercè Cladellas
  • Jordi Bruguera
  • Josep Comín
  • Joan Vila
  • Elisabeth de Jaime
  • Julio Martí
  • Miquel Gomez
چکیده

AIMS To assess the level of pre-operative haemoglobin (HB) as a risk marker for morbidity and mortality in the early post-operative period of patients who underwent elective valve replacement. METHODS AND RESULTS Between January 1998 and March 2004, clinical and outcomes data were collected for the 201 patients who had elective valve replacement. For each gender, the criterion to choose the best cut-off point was that which achieved the maximum likelihood after several General Additive Model models performed in a Bootstrap procedure. The best cut-off point obtained for pre-operative HB was 12 g/dL. Overall peri-operative mortality (deaths occurring during hospital period or within 30 days) was 9.5%. After adjusting well-known independent pre-operative risk factors for operative mortality, pre-operative HB <12 g/dL was identified as an independent predictor for in-hospital mortality (OR, 3.23; 95% CI, 1.09-9.55; P = 0.03). Also adjusting for EuroScore, pre-operative HB remained significant (OR, 3.64; 95% CI, 1.32-10.06; P = 0.01). The same model was applied to post-operative morbidity, and pre-operative HB <12 g/dL was identified as an independent predictor with and without EuroScore (OR, 4.67; 95% CI, 2.03-10.71; P < 0.001), (OR, 5.18; 95% CI, 2.18-12.3; P < 0.001), respectively. CONCLUSION In patients undergoing elective valve replacement pre-operative HB <12 g/dL is a risk marker of in-hospital mortality and serious adverse outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left Atrial Volume and Post-Operative Atrial Fibrillation after Aortic Valve Replacement.

Post-operative atrial fibrillation (POAF) after valve surgery is associated with increased morbidity and mortality. Risk factors identified in the past to predict POAF are of moderate accuracy. We performed a retrospective analysis of 139 patients undergoing aortic valve replacement for aortic stenosis. Post-operative AF occurred in 44% of the patients. In multivariate analysis only left atrial...

متن کامل

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

Cystatin C blood level as a risk factor for death after heart surgery.

AIMS Pre-operative renal dysfunction is a known risk factor for mortality and morbidity after heart surgery. Despite limited accuracy, serum creatinine is widely used to estimate glomerular filtration rate (GFR). Cystatin C is more accurate for assessing GFR. The aim of the present study was to assess associations between GFR estimated from serum cystatin C levels before heart surgery and hospi...

متن کامل

Long-term follow-up of morbidity and mortality after aortic valve replacement with a mechanical valve prosthesis.

AIMS The aim of this study was to determine the incidence of valve-related complications in patients with a mechanical aortic valve prosthesis and to identify risk factors for an adverse outcome. METHODS AND RESULTS In the 424 patients, event-free survival rates 5 and 10 years after aortic valve replacement were 62% and 37%, respectively. The linearized incidence of thromboembolic events was ...

متن کامل

عوامل موثر بر علل جراحی مجدد دریچه های مصنوعی قلب و بقاء زودرس بعد عمل، بیمارستان امام، 80-1370

Prosthetic valve re-operation has greater mortality and morbidity than primary valve replacement. By recognition of factors influencing on causes of redo operation and preoperative survival, one can select appropriate prosthesis at primary valve replacement and when operation performed at appropriate time, surgical risk can be reduced.Methods and Materials: Two hundred patients that underwent p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 27 9  شماره 

صفحات  -

تاریخ انتشار 2006