Blinded comparison of a direct immunofluorescent monoclonal antibody staining method and a Giemsa staining method for identification of Pneumocystis carinii in induced sputum and bronchoalveolar lavage specimens of patients infected with human immunodeficiency virus.

نویسندگان

  • J S Wolfson
  • M A Waldron
  • L S Sierra
چکیده

A new direct immunofluorescence monoclonal antibody (DFA) method (Genetic Systems, Inc., Seattle, Wash.) for identification of Pneumocystis carinii in induced sputum and bronchoalveolar lavage specimens was compared in a blinded study with an established Giemsa stain method. We evaluated 148 consecutive clinical specimens from 104 patients with the following results. For the 67 patients (64%) infected with the human immunodeficiency virus (HIV), 49 were initially negative by both the DFA and the Giemsa methods, none were negative by DFA and positive by Giemsa, 6 were positive by DFA and negative by Giemsa, and 12 were positive by both methods, for a sensitivity and a negative predictive value of greater than 99%. For the six patients positive by DFA and negative by Giemsa, all were positive by both methods on evaluation of subsequently obtained clinical specimens, suggesting a specificity of greater than 99% and a false-positive rate of less than 1%. For 37 patients whose HIV status was negative or unknown, 35 were negative by both methods and 2 were positive by DFA and negative by Giemsa. The DFA method was simple to perform and required less time for scoring of stained slides than the Giemsa method, but care had to be taken to avoid false-positive readings due to extraneous fluorescence. This study indicates that the DFA method represents an advance as a sensitive, simple, and rapid way to identify P. carinii in induced sputum and bronchoalveolar lavage specimens from HIV-infected patients and suggests greater sensitivity of the DFA than the Giemsa method in this patient population.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Small volume bronchoalveolar lavage used in diagnosing Pneumocystis carinii pneumonia in HIV-infected patients.

To determine the volume of bronchoalveolar lavage (BAL) fluid necessary to diagnose Pneumocystis carinii pneumonia (PCP) in immunocompromised patients, specimens from 25 patients were evaluated. Twenty-one patients were HIV infected. BAL was performed using three to four 60-mL aliquots of room temperature, sterile, saline solution. Each syringe of BAL effluent was numbered and its volume was me...

متن کامل

Pneumocystis carinii pneumonia: detection of parasites in sputum and bronchoalveolar lavage fluid by monoclonal antibodies.

Diagnosis of pneumocystis pneumonia is based on identifying Pneumocystis carinii cytochemically in material from the lung. The silver methenamine staining methods most commonly used are technically difficult and lack specificity. The diagnostic value of immunocytological identification of the parasite was evaluated by using mouse monoclonal antibody 3F6, specific for human pneumocystis, to iden...

متن کامل

Comparison of monoclonal antibody and calcofluor white stains for the detection of Pneumocystis carinii from respiratory specimens.

Three monoclonal antibody staining kits, from Genetic Systems, Disease Detection International, and Meridian Diagnostics, were compared with calcofluor white for the direct detection of Pneumocystis carinii in respiratory specimens. Of the 150 specimens tested, 23 were found positive for P. carinii by any of the four stains; 13 were bronchoalveolar lavage, 7 were induced sputum and 3 were expec...

متن کامل

Rapid detection of Pneumocystis carinii using a direct fluorescent monoclonal antibody stain.

A collaborative study was undertaken at two institutions to assess the performance of a direct fluorescent-antibody stain for the detection of Pneumocystis carinii in respiratory specimens from patients with known or suspected human immunodeficiency virus type 1 infections. A total of 163 specimens (125 induced sputa, 37 bronchoalveolar lavage fluids, and 1 tracheal aspirate) from 124 patients ...

متن کامل

Comparison of PCR and standard cytological staining for detection of Pneumocystis carinii from respiratory specimens from patients with or at high risk for infection by human immunodeficiency virus.

The detection of Pneumocystis carinii DNA by PCR was compared with routine cytologic staining techniques (CYT). A total of 284 clinical respiratory specimens, including 137 bronchoalveolar lavage (BAL), 63 bronchoalveolar washing, 63 sputum, and 21 induced sputum samples, obtained from patients with or at high risk for human immunodeficiency virus infection were evaluated. Eighty specimens were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 28 9  شماره 

صفحات  -

تاریخ انتشار 1990