A novel infusion-drainage device to assess lower urinary tract function in neuro-imaging.
نویسندگان
چکیده
OBJECTIVE To evaluate the applicability and precision of a novel infusion-drainage device (IDD) for standardized filling paradigms in neuro-urology and functional magnetic resonance imaging (fMRI) studies of lower urinary tract (LUT) function/dysfunction. SUBJECTS/PATIENTS AND METHODS The IDD is based on electrohydrostatic actuation which was previously proven feasible in a prototype setup. The current design includes hydraulic cylinders and a motorized slider to provide force and motion. Methodological aspects have been assessed in a technical application laboratory as well as in healthy subjects (n=33) and patients with LUT dysfunction (n=3) undergoing fMRI during bladder stimulation. After catheterization, the bladder was pre-filled until a persistent desire to void was reported by each subject. The scan paradigm comprised automated, repetitive bladder filling and withdrawal of 100 mL body warm (37 °C) saline, interleaved with rest and sensation rating. Neuroimaging data were analysed using Statistical Parametric Mapping version 12 (SMP12). RESULTS Volume delivery accuracy was between 99.1±1.2% and 99.9±0.2%, for different flow rates and volumes. Magnetic resonance (MR) compatibility was demonstrated by a small decrease in signal-to-noise ratio (SNR), i.e. 1.13% for anatomical and 0.54% for functional scans, and a decrease of 1.76% for time-variant SNR. Automated, repetitive bladder-filling elicited robust (P = 0.05, family-wise error corrected) brain activity in areas previously reported to be involved in supraspinal LUT control. There was a high synchronism between the LUT stimulation and the blood oxygenation level-dependent (BOLD) signal changes in such areas. CONCLUSION We were able to develop an MR-compatible and MR-synchronized IDD to routinely stimulate the LUT during fMRI in a standardized manner. The device provides LUT stimulation at high system accuracy resulting in significant supraspinal BOLD signal changes in interoceptive and LUT control areas in synchronicity to the applied stimuli. The IDD is commercially available, portable and multi-configurable. Such a device may help to improve precision and standardization of LUT tasks in neuro-imaging studies on supraspinal LUT control, and may therefore facilitate multi-site studies and comparability between different LUT investigations in the future.
منابع مشابه
Simplified Dynamic Phantom for Pediatric Renography: A Description of Instrument and Its Performance
Objective(s): Renography is used for the diagnostic evaluation of pediatric patients with a suspected obstruction of urinary tract or impaired renal function. The recommended dose for children have been released by the European Association of Nuclear Medicine, Society of Nuclear Medicine and Molecular Imaging, and Japanese Society of Nuclear Medicine. Since acquisition counts in dynamic scintig...
متن کاملProtocol for a prospective magnetic resonance imaging study on supraspinal lower urinary tract control in healthy subjects and spinal cord injury patients undergoing intradetrusor onabotulinumtoxinA injections for treating neurogenic detrusor overactivity
BACKGROUND The control of the lower urinary tract is a complex, multilevel process involving both the peripheral and central nervous system. Due to lesions of the neuraxis, most spinal cord injury patients suffer from neurogenic lower urinary tract dysfunction, which may jeopardise upper urinary tract function and has a negative impact on health-related quality of life. However, the alterations...
متن کاملUrodynamic Investigation: A Valid Tool to Define Normal Lower Urinary Tract Function?
OBJECTIVES To evaluate whether urodynamic investigation (UDI), the gold standard to assess refractory lower urinary tract symptoms (LUTS), is appropriate to select healthy volunteers with apparent normal lower urinary tract function as control subjects for comparative studies. SUBJECTS AND METHODS 42 healthy subjects (22 women, mean age 32±10 years; 20 men, mean age 37±12 years) without LUTS ...
متن کاملPrenatal bladder drainage in the management of fetal lower urinary tract obstruction: a systematic review and meta-analysis.
OBJECTIVE To estimate the effect of prenatal bladder drainage on perinatal survival in fetuses with lower urinary tract obstruction. DATA SOURCES Relevant articles were identified by searching the databases MEDLINE (1966-2002), EMBASE (1988-2002), and the Cochrane library (2000;4). METHODS OF STUDY SELECTION Studies were selected if the effect of prenatal bladder drainage (vesicocentesis, v...
متن کاملCross-sectional imaging of complicated urinary infections affecting the lower tract and male genital organs
Complicated urinary tract infections (C-UTIs) are those associated with structural or functional genitourinary abnormalities or with conditions that impair the host defence mechanisms, leading to an increased risk of acquiring infection or failing therapy. C-UTIs occur in patients with risk factors such as neurogenic dysfunction, bladder outlet obstruction, obstructive uropathy, bladder cathete...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BJU international
دوره 119 2 شماره
صفحات -
تاریخ انتشار 2017