Experimental Study on the Performance of Water Source Trans-Critical CO2 Heat Pump Water Heater

نویسندگان

  • Xiufang Liu
  • Changhai Liu
  • Ze Zhang
  • Liang Chen
  • Yu Hou
چکیده

The effect of the discharge pressure on the performance of the trans-critical CO2 heat pump with a low gas-cooler outlet temperature is experimentally investigated on a test rig of water source heat-pump water heater. The optimal discharge pressure of the trans-critical CO2 heat pump is investigated under different external operation conditions. When the tap-water temperature is low, the characteristic of the S-shape isotherm at the supercritical region has little effect on the occurrence of the optimal discharge pressure; while the mass flow rate of CO2, the suction pressure and the gas-cooler outlet temperature play a significant role in determining the emergence of the optimal discharge pressure. At the optimal discharge pressure, the COP reaches the peak; however, the corresponding heating capacity is still lower than its maximum, which is reached as the discharge pressure is slightly above the optimal discharge pressure. Reducing the tap-water flowrate or increasing the water-source temperature can increase the optimal discharge pressure. The COP is positively dependent on both the tap-water flowrate and the water-source temperature. In addition, the tap-water flowrate has a negligible influence on the maximum heating capacity while increasing the water-source temperature can greatly enhance the heating capacity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experiences with Application of a CO2 Reciprocating Piston Compressor for a Heat Pump Water Heater

This paper describes some of the challenges experienced in the application of a carbon dioxide reciprocating piston compressor to a water heating heat pump. Due to the characteristics of CO2 in a trans-critical cycle, including high pressures, high discharge temperatures, and high solubility in oil, particular difficulties may be experienced such as reduced bearing reliability caused by bearing...

متن کامل

Experimental Investigation on the Influence of Refrigerant Charge on the Performance of Trans-critical CO2 Water-Water Heat Pump

For the environmentally aware, natural refrigerant such as CO2 is recommended and pursued by researchers for refrigerators. In this paper, a transcritical CO2 heat pump system was set up to investigate the influence of refrigerant charge on the performance of a small-sized heat pump water heater. The transcritical CO2 heat pump system was composed of a rotary compressor, a tube-in-tube evaporat...

متن کامل

Development and validation of static simulation model for CO2 heat pump

A simulation model for the CO2 heat pump water heater was developed and validated in this study. Component models of the gas cooler, evaporator, compressor, and expansion valve were constructed with careful consideration for the heat transfer performances. To validate the simulation model, experiments were carried out using an actual CO2 heat pump water heater (water heating capacity: 22.3 kW; ...

متن کامل

Performance Comparison of Single-stage and Two-stage Hermetic Rotary CO2 Compressor

As a natural refrigerant, CO2 gets more and more attention in recent years. The CO2 system runs at a trans-critical cycle. This leads to a high running pressure and high pressure difference for the CO2 compressor. In this paper the single stage and two stage rolling piston compressors with same displacement have been developed for CO2 heat pump water heater. And a comprehensive performance comp...

متن کامل

Field Evaluation for Air-source Transcritical CO2 Heat Pump Water Heater with Optimal Pressure Control

Several optimal discharge pressure correlations for transcritical CO2 heat pump in literature have been discussed in this paper. Most of them are related to the ambient temperature, the evaporation temperature and the gas cooler outlet temperature. A revised optimal discharge pressure model as the function of ambient temperature and water outlet temperature is developed based on earlier experim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017