Tomographic analysis of CO absorption in a low-pressure flame.
نویسندگان
چکیده
Tomographic analysis is used to provide a correction to low-pressure stoichiometric premixed CH(4)/O(2) flame temperatures measured with tunable diode laser absorption spectroscopy employing CO two-line thermometry. It is shown that flame temperatures measured with line-of-sight-based two-line thermometry are always too low and that the correction to the observed temperature is a nonlinear function of the height above the burner surface. It is also shown that, at a given height in the flame, a constant temperature across the flame does not imply that vibrational populations are constant and that, at low pressures (<20 Torr), the flame spreads radially beyond the burner diameter and so may no longer be approximated by a one-dimensional model.
منابع مشابه
Solid phase extraction of trace cobalt (II) in industrial wastewaters by modified nanotube carbon carboxyl and its determination with flame atomic spectroscopy
Applying a simple and selective sample preparation procedure prior to instrumental analysis is the most important and crucial step in an analytical process. Up to now, various sample preparation techniques based on solid phase extraction (SPE) systems have been developed to isolate various types of analytes from different matrices. In the method presented for preconcentration and measurement of...
متن کاملSolid phase extraction of trace cobalt (II) in industrial wastewaters by modified nanotube carbon carboxyl and its determination with flame atomic spectroscopy
Applying a simple and selective sample preparation procedure prior to instrumental analysis is the most important and crucial step in an analytical process. Up to now, various sample preparation techniques based on solid phase extraction (SPE) systems have been developed to isolate various types of analytes from different matrices. In the method presented for preconcentration and measurement of...
متن کاملThe Equilibrium Solubility of Carbon Dioxide in the Mixed Aqueous Solutions of Triisopropanolamine and Monoethanolamine in the Range 30-70 C and Low Partial Pressures
The equilibrium solubility data of CO2 in the various aqueous blends of triisopropanolamine (TIPA) + monoethanolamine (MEA) with the total alkanolamine concentration of 2 mole / dm3 were measured at the temperatures of 30, 40, 50, 60 and 70 oC and CO2 partial pressures below 100 kPa. The experiments were done in an atmospheric gas absorption syste...
متن کاملDispersive liquid–liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry for determination trace amount of cobalt in water samples
An efficient, rapid, simple, and highly selective dispersive liquid–liquid microextraction basedon solidification of floating organic drop (DLLME-SFOD), combined with flame atomicabsorption spectrometry was developed for preconcentration and determination of trace amountsof cobalt in water samples. In this method, an appropriate mixture of acetone and1-undecanol was injected rapidly into the aq...
متن کاملExtraction of Co(II) by Isocyanate Treated Graphite Oxides (iGOs) Adsorbed on Surfactant Coated C18 Before Determination by FAAS
A simple, highly sensitive, accurate and selective method for determination of trace amounts of Co(II) in water samples is presented. Isocyanate treated graphite oxides (iGOs) solid phase extraction adsorbent was synthesized by covalently isocyanate onto the surfaces of graphite oxides. The stability of a chemically (iGOs) especially in concentrated hydrochloric acid which was then used as a re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 34 18 شماره
صفحات -
تاریخ انتشار 1995