Characteristics of a first-generation x-ray system.

نویسندگان

  • Martijn Kemerink
  • Tom J Dierichs
  • Julien Dierichs
  • Hubert J M Huynen
  • Joachim E Wildberger
  • Jos M A van Engelshoven
  • Gerrit J Kemerink
چکیده

PURPOSE To compare the antiquated x-ray system of Hoffmans and van Kleef (circa 1896) with modern x-ray equipment in terms of radiation dose, x-ray beam properties, image quality, and electrical parameters. MATERIALS AND METHODS The antiquated x-ray system consisted of a Ruhmkorff inductor, battery, and Crookes tube. The radiation dose rate, x-ray beam properties, and electrical characteristics of this system were determined. A modern computed radiography plate was used to compare images of a hand specimen obtained by using the antiquated system with images obtained by using the modern system. RESULTS A peak voltage of 73 kV was obtained with an 8-V battery. With Crookes tube number 9, the half-value layer of the generated x-rays was 0.56 mm Al. Pinhole images showed that the x-rays originated from an extended area of the glass wall, causing image blurring. When measured on the skin of a hand specimen, the radiation dose of the antiquated system was about 10 times greater than that of the modern system for the same detector signal. The estimated skin dose was about 74 mGy for the antiquated system and 0.05 mGy for the modern system. The corresponding exposure times were 90 minutes and 21 msec. CONCLUSION Radiation dose and exposure time of the antiquated system were greater than those of the modern system by about three and five orders of magnitude, respectively. Images of the hand specimen obtained with the antiquated system were severely blurred but were still awe inspiring, considering the simplicity of the system. SUPPLEMENTAL MATERIAL http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101899/-/DC1.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical klystron FEL scheme for x-ray coherent harmonic generation at ISLF storage ring

The possibility of inserting an optical klystron on the storage ring of an Iranian Light Source Facility as a Synchrotron Radiation Free electron Laser for coherence harmonic generation in the soft x-ray spectrum has been studied. The study has been performed using the 3D FEL simulation code GENESIS 1.3 and in accordance with the available characteristic parameters of ISLF. Different potential ...

متن کامل

Evaluation of a systemic change of Superficial X-ray tube characteristics

Introduction: Very low, Low and Medium X-ray machines are used extensively for Superficial Radiation Therapy mostly used for Basal Cell, Squamous Cell Carcinoma, and Melanoma skin cancers. In most of cases, Superficial X-ray Therapy (SXRT) is preferred to Electron beams generated using a linear accelerator. SXRT tube characteristics may vary with the use of the machine for a lo...

متن کامل

Generation of Nonclassical States of the Radiation Field in the System of a Single Trapped Atom in a Cavity within the First Order of the Lamb-Dicke Approximation

In this paper, we propose a theoretical scheme for the generation of non-classical states of the cavity field in a system of a single trapped atom via controlling the Lamb-Dicke parameter. By exploiting the super-operator method, we obtain an analytical expression for the density operator of the system by which we examine the dynamical behaviors of the atomic population inversion, the phase-spa...

متن کامل

Nano Dispersed Metal-Ceramic Composite Materials of the Ni-SiO2 system

In the organic field effect transistors (OFETs) generation, the silicon gate oxide is 1-2 nm thick. A shrinking of this thickness down to less than 1 nm for the next generation will led to a couple of orders of magnitude increase in tunnelling as well as leakage currents. NiO-SiO2 can be used in a variety of devices, such as in circuit boards and detectors, including sensors, due to its porous ...

متن کامل

X-ray radiation and the risk of multiple sclerosis: Do the site and dose of exposure matter?

  Background: The sporadic cases of radiation-activated multiple sclerosis (MS) has been previously described, with a few studies focused on the relationship between radiation and the risk of MS. The aim of our study was to evaluate the association between history of X-ray radiation and MS.   Methods : This case-control study was conducted on 150 individuals including 65 MS patients and 85 age-...

متن کامل

Static Security Constrained Generation Scheduling Using Sensitivity Characteristics of Neural Network

This paper proposes a novel approach for generation scheduling using sensitivitycharacteristic of a Security Analyzer Neural Network (SANN) for improving static securityof power system. In this paper, the potential overloading at the post contingency steadystateassociated with each line outage is proposed as a security index which is used forevaluation and enhancement of system static security....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 259 2  شماره 

صفحات  -

تاریخ انتشار 2011