Anterior but not posterior choroid changed before and during Valsalva manoeuvre in healthy Chinese: a UBM and SS-OCT study
نویسندگان
چکیده
PURPOSE To determine if the anterior choroid is involved in ocular change during the Valsalva manoeuvre (VM). MATERIALS AND METHODS Fifty-three healthy volunteers aged 18-65 years with normal visual field test results and no history of intraocular pressure (IOP) exceeding 21 mm Hg were recruited. Anterior and posterior choroidal changes before and during VM were recorded by ultrasound microscope and swept-source optical coherence tomography, respectively. Parameters of the anterior segment included ciliary body thickness (CBT0), thickness of the choroid at a distance of 4 mm from the root of the iris (CT4), anterior placement of the ciliary body (APCB) and trabecular-ciliary angle (TCA). Thickness of different layers of retina and posterior choroid were also measured and compared before and during VM. IOP, blood pressure (BP), heart rate (HR), axial length, spherical equivalent refractive error and pupil diameter (PD) were also recorded and analysed. RESULTS VM caused elevated IOP, systolic BP, diastolic BP and increased HR. There was a significant increase in anterior parameters including CBT0, CT4 and APCB (p<0.001), but not in TCA or PD (p>0.05). The mean change of CBT0, CT4 and APCB were: from 1.00±0.09 mm to 1.11±0.10 mm (p<0.001), from 0.29±0.04 mm to 0.36±0.05 mm (p<0.001), from 0.76±0.11 mm to 0.88±0.13 mm (p<0.001), respectively. However, there is no significant change in posterior choroid (from 215.74±60.23 µm to 214.82±61.32 µm, p=0.17). CONCLUSION We found that VM did not affect the posterior choroid, but it did cause thickening of the anterior choroid and the ciliary body, both of which led to a larger anterior placement of the ciliary body and a narrowed anterior chamber. The anterior (but not the posterior) choroid could be related to IOP elevation and a narrowed anterior chamber in primary angle closure diseases.
منابع مشابه
Anterior Choroidal Thickness Increased in Primary Open-Angle Glaucoma and Primary Angle-Closure Disease Eyes Evidenced by Ultrasound Biomicroscopy and SS-OCT.
Purpose To compare the anterior and posterior choroid thickness (ACT and PCT, respectively) in primary open-angle glaucoma (POAG), primary angle-closure disease (PACD), and healthy control subjects. Methods A total of 29 POAG patients (56 eyes), 37 PACD patients (64 eyes), and 34 healthy volunteers (68 eyes) were enrolled in this study; 50 POAG eyes were divided into 25 early/moderate-stage a...
متن کاملAnterior and Posterior Ocular Biometry in Healthy Chinese Subjects: Data Based on AS-OCT and SS-OCT
BACKGROUND To measure the anterior and posterior ocular biometric characteristics concurrently and to determine the relationship between the iris and choroid in healthy Chinese subjects. METHODS A total of 148 subjects (270 eyes) were enrolled in this cross-section study. The anterior and posterior ocular biometric characteristics were measured simultaneously by anterior segment optical coher...
متن کاملIridotrabecular contact observed using anterior segment three-dimensional OCT in eyes with a shallow peripheral anterior chamber.
PURPOSE To evaluate the prevalence and range of iridotrabecular contact (ITC) in eyes with a shallow peripheral anterior chamber (AC) by using anterior segment swept-source optical coherence tomography (AS-SS-OCT) and to compare the results with those obtained with ultrasound biomicroscopy (UBM) and gonioscopy. METHODS Forty-three shallow peripheral AC eyes in 43 consecutive patients underwen...
متن کاملAnterior Displacement of Lamina Cribrosa during Valsalva Maneuver in Young Healthy Eyes
PURPOSE To investigate lamina cribrosa (LC) displacement during the Valsalva maneuver in young healthy eyes using enhanced depth imaging (EDI) spectral-domain optical coherence tomography (SD-OCT). METHODS Forty-eight eyes of 48 young healthy volunteers (age range: 20-34 years) underwent intraocular pressure (IOP) measurement by Goldmann applanation tonometry as well as Cirrus HD-OCT scans be...
متن کاملComparison of high-resolution Scheimpflug and high-frequency ultrasound biomicroscopy to anterior-segment OCT corneal thickness measurements
BACKGROUND The purpose of this study was to compare and correlate central corneal thickness in healthy, nonoperated eyes with three advanced anterior-segment imaging systems: a high-resolution Scheimpflug tomography camera (Oculyzer II), a spectral-domain anterior-segment optical coherence tomography (AS-OCT) system, and a high-frequency ultrasound biomicroscopy (HF-UBM) system. METHODS Fifty...
متن کامل