Optimizing contrast agents with respect to reducing beam hardening in nonmedical X-ray computed tomography experiments.

نویسندگان

  • Yoshito Nakashima
  • Tsukasa Nakano
چکیده

Iodine is commonly used as a contrast agent in nonmedical science and engineering, for example, to visualize Darcy flow in porous geological media using X-ray computed tomography (CT). Undesirable beam hardening artifacts occur when a polychromatic X-ray source is used, which makes the quantitative analysis of CT images difficult. To optimize the chemistry of a contrast agent in terms of the beam hardening reduction, we performed computer simulations and generated synthetic CT images of a homogeneous cylindrical sand-pack (diameter, 28 or 56 mm; porosity, 39 vol.% saturated with aqueous suspensions of heavy elements assuming the use of a polychromatic medical CT scanner. The degree of cupping derived from the beam hardening was assessed using the reconstructed CT images to find the chemistry of the suspension that induced the least cupping. The results showed that (i) the degree of cupping depended on the position of the K absorption edge of the heavy element relative to peak of the polychromatic incident X-ray spectrum, (ii) (53)I was not an ideal contrast agent because it causes marked cupping, and (iii) a single element much heavier than (53)I ((64)Gd to (79)Au) reduced the cupping artifact significantly, and a four-heavy-element mixture of elements from (64)Gd to (79)Au reduced the artifact most significantly.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Beam hardening correction and its influence on the measurement accuracy and repeatability for CT dimensional metrology applications

The beam hardening effect is one of the major artifacts of X-ray computed tomography. It not only complicates medical inspection and material analysis, but also influences the accuracy and repeatability of dimensional measurements. Therefore, many efforts have been devoted to develop beam hardening correction methods since the early 1970s. In practice, the combination of hardware filters (pre-f...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Multi-Material Beam Hardening Correction(MMBHC) in Computed Tomography

In computed tomography (CT), the nonlinear attenuation characteristics of polychromatic X-rays cause beam hardening artifacts in the reconstructed images. State-of-theart methods to correct the beam hardening effect are mostly single material precorrections (e.g. water-precorrection), which are far less efficient when more than one material is present in the field of measurement. The use of tho...

متن کامل

Assessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method

Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...

متن کامل

The Application of Beam Hardening Correction for Industrial X-ray Computed Tomography

X-ray computed tomography (CT) is a non-destructive, radiographic scanning technique that enables the visualisation of both the internal geometry and the composition of a workpiece; X-ray CT is therefore well suited for non-destructive inspection tasks. Several physical processes reduce the quality of CT images, and therefore influence both qualitative and quantitative analyses made from CT dat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of X-ray science and technology

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 2014