Dynamic flow alignment of flagellar axonemes for low-angle X-ray fiber diffraction analysis

نویسندگان

  • Shinji KAMIMURA
  • Takaaki SUGIYAMA
  • Yasunobu SUGIMOTO
  • Katsuzo WAKABAYASHI
چکیده

236-1 Fig.1 Schematic drawing of the apparatus for X-ray diffraction experiment. (A) Specimen was placed between two parallel discs, one of which was rotated with a constant rate (0-5 s) Through a chamber window made of Kapton film, X-ray beam was introduced through the specimen suspension and diffraction signals from aligned filaments were recorded with a Hamamatsu cooled CCD camera (camera length, ca. 1m). B illustrates the relationship between the X-ray beam path and flow-rate gradient given to the specimen. 15A/2005G390 Dynamic flow alignment of flagellar axonemes for low-angle X-ray fiber diffraction analysis

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

X-Ray Fiber Diffraction Recordings from Oriented Demembranated Chlamydomonas Flagellar Axonemes.

The high homology of its axonemal components with humans and a large repertoire of axonemal mutants make Chlamydomonas a useful model system for experiments on the structure and function of eukaryotic cilia and flagella. Using this organism, we explored the spatial arrangement of axonemal components under physiological conditions by small-angle x-ray fiber diffraction. Axonemes were oriented in...

متن کامل

The susceptibility of pure tubulin to high magnetic fields: a magnetic birefringence and x-ray fiber diffraction study.

The orientational behavior of microtubules assembled in strong magnetic fields has been studied. It is shown that when microtubules are assembled in a magnetic field, they align with their long axis parallel to the magnetic field. The effect of several parameters known to affect the microtubule assembly are investigated with respect to their effect on the final degree of alignment. Aligned samp...

متن کامل

Low angle x-ray diffraction studies of HeLa metaphase chromosomes: effects of histone phosphorylation and chromosome isolation procedure

To test whether gross changes in chromatin structure occur during the cell cycle, we compared HeLa mitotic metaphase chromosomes and interphase nuclei by low angle x-ray diffraction. Interphase nuclei and metaphase chromosomes differ only in the 30-40-nm packing reflection, but not in the higher angle part of the x-ray diffraction pattern. Our interpretation of these results is that the transit...

متن کامل

Protein fiber linear dichroism for structure determination and kinetics in a low-volume, low-wavelength couette flow cell.

High-resolution structure determination of soluble globular proteins relies heavily on x-ray crystallography techniques. Such an approach is often ineffective for investigations into the structure of fibrous proteins as these proteins generally do not crystallize. Thus investigations into fibrous protein structure have relied on less direct methods such as x-ray fiber diffraction and circular d...

متن کامل

Structural hysteresis in dragline spider silks induced by supercontraction: An x-ray fiber micro-diffraction study.

Interaction with water causes shrinkage and significant changes in the structure of spider dragline silks, which has been referred to as supercontraction in the literature. Preferred orientation or alignment of protein chains with respect to the fiber axis is extensively changed during this supercontraction process. Synchrotron x-ray micro-fiber diffraction experiments have been performed on Ne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006