Effect of vertical placement angle on the insertion torque of mini-implants in human alveolar bone
نویسندگان
چکیده
Objective: The aim of the present ex-vivo study was to evaluate the effect of the vertical placement angle of mini-implants on primary stability by analyzing maximum insertion torque (MIT). Methods: Mini-implants were placed in 30 human cadavers, inserted at either a 90° or 60° angle to the buccal surface of the maxillary first molar. Out of 60 self-drilling mini-implants used, half were of the cylindrical type and half were of the conical type. Primary stability was assessed by means of measuring the MIT. Data were subjected to analysis of variance (ANOVA) and Newman-Keuls tests. A significance level of 5% was adopted. Results: The MIT was higher for both mini-implant types when they were placed at a 90° angle (17.27 and 14.40 Ncm) compared with those placed at a 60° angle (14.13 and 11.40 Ncm). Conclusions: MIT values were differed according to the vertical mini-implant placement angle in the maxillary posterior area. Regardless of the type of mini-implant used, placement at a 90° angle resulted in a higher MIT.
منابع مشابه
Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque
OBJECTIVE To determine the unique contribution of geometrical design characteristics of orthodontic mini-implants on maximum insertion torque while controlling for the influence of cortical bone thickness. METHODS Total number of 100 cylindrical orthodontic mini-implants was used. Geometrical design characteristics of ten specimens of ten types of cylindrical self-drilling orthodontic mini-im...
متن کاملInsertion Torques of Self-Drilling Mini-Implants in Simulated Mandibular Bone: Assessment of Potential for Implant Fracture.
PURPOSE Fracture of orthodontic mini-implants during insertion is a limiting factor for their clinical success. The purpose of this study was to determine the fracture potential of commonly used self-drilling orthodontic mini-implants when placed into simulated thick, dense mandibular bone. MATERIALS AND METHODS Six mini-implant systems were assessed for the potential for fracture (Aarhus, Me...
متن کاملInfluence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.
BACKGROUND Clinical studies show promising outcomes with implants inserted at the time of extraction. However, this often results in an initial bone defect at the marginal region which preferably should heal for an optimal function. Therefore, monitoring of these implants is vital. PURPOSES The aims of this study were to determine the initial stability of implants placed into fresh extraction...
متن کاملGuided bone regeneration: A literature review
Guided bone regeneration (GBR) is a reconstructive procedure of alveolar ridge using membranes. This procedure is indicated when there is no sufficient bone for implantation, or in the case of optimal implant installation for esthetic or functional needs. GBR can be performed before implant placement, when there is not enough bone for initial stability of implants and less predictable outcomes ...
متن کاملRotational resistance of surface-treated mini-implants.
OBJECTIVE To test the hypothesis that there is no difference in the stability and resistance to rotational moments of early loaded sandblasted and acid-etched (SLA) mini-implants and those of machined-surface implants of the same size and shape. MATERIALS AND METHODS A randomized complete block design was used in 12 skeletally mature male beagle dogs. Ninety-six orthodontic mini-implants were...