Pii: S1388-2457(99)00150-9
نویسندگان
چکیده
Objectives: Acute poliomyelitis causes degeneration of anterior horn cells, followed by denervation. Reinnervation and muscle ®bre hypertrophy are mechanisms that compensate this loss of neurones. Concentric needle EMG (CNEMG) and macro EMG are two methods to assess the magnitude of initial involvement and the compensatory reinnervation. The aim of this study is to explore the difference between CNEMG and macro EMG describing the status of the motor unit in patients previously affected by polio. Methods: Macro and concentric needle EMG investigations were performed in 261 muscles in 121 patients with a remote history of polio. Results: CNEMG was abnormal in 211 muscles, macro EMG was abnormal in 246 muscles. The macro amplitude was 3±4 times `more abnormal' than CNEMG amplitude relative to the reference values. CNEMG duration was less abnormal and showed only weak correlation with macro amplitudes. The most likely explanation for the difference in magnitude of deviation from reference values for CNEMG and macro EMG, is a more pronounced `phase cancellation' between single ®bre action potentials in CNEMG. This is supported by simulation studies reported here. Conclusions: In conclusion macro EMG better re ̄ects the size of the motor unit than the CNEMG. For detection of concomitant disorders, CNEMG is the method of choice. q 1999 Elsevier Science Ireland Ltd. All rights reserved.
منابع مشابه
Pii: S1388-2457(99)00005-x
About two-thirds of epilepsy patients who learn to control their slow cortical potential shifts (SCP) reduce their seizure rate, but the remaining third does not demonstrate clinical improvement. In the present study, this ®nding was replicated in a group of 27 patients with focal epilepsy. We found that patients who consistently produced larger negative SCP in all conditions during the ®rst ph...
متن کاملPii: S1388-2457(00)00527-7
Objective: A system for electrode placement is described. It is designed for studies on topography and source analysis of spontaneous and evoked EEG activity. Method: The proposed system is based on the extended International 10±20 system which contains 74 electrodes, and extends this system up to 345 electrode locations. Results: The positioning and nomenclature of the electrode system is desc...
متن کاملPii: S1388-2457(02)00297-3
For algorithm developers, this review details recent approaches to the problem, compares the accuracy of various algorithms, identifies common testing issues and proposes some solutions. For the algorithm user, e.g. electroencephalograph (EEG) technician or neurologist, this review provides an estimate of algorithm accuracy and comparison to that of human experts. Manuscripts dated from 1975 ar...
متن کاملPii: S1388-2457(02)00163-3
Objectives: This report provides a systematic longitudinal analysis of the EEG from infancy into early childhood. Particular emphasis is placed on the empirical confirmation of a 6–9 Hz alpha-range frequency band that has previously been used in the infant EEG literature. Methods: EEG data in 1-Hz bins from 3 to 12 Hz were analyzed from a longitudinal sample of 29 participants at 5, 10, 14, 24,...
متن کاملPii: S1388-2457(99)00011-5
Objectives: By using the Wavelet Transform, a time frequency representation with nearly optimal resolution, we studied responses to stimulation in the `alpha' range (10 Hz). Methods: Visual evoked responses of 10 healthy subjects were studied with 3 different stimulus types (no-task VEP, non-target and target stimulus). Results: Upon all the stimulus types, event-related responses in the 10 Hz ...
متن کامل