Novel internal controls for real-time PCR assays.

نویسنده

  • Frederick S Nolte
چکیده

In the 19 years since the first descriptions of the PCR (1 ), nucleic acid amplification methods have made the transition from research to clinical laboratories. Molecular diagnostics are now firmly established as part of laboratory medicine, with applications in genetics, oncology, pharmacology, and infectious disease. Routine diagnostic applications of these methods have been made possible by the thoughtful use of controls coupled with laboratory practices intended to reduce false-positive and -negative results (2–4). Nucleic acid amplification assays are prone to inhibition by a variety of substances found in clinical samples. Although the identities and biochemical mechanisms of action of many inhibitors remain unclear, bile salts and complex polysaccharides in feces (5 ), heme in blood (6 ), and urea in urine (7 ) have all been shown to inhibit PCR, probably through interference with the binding and/or polymerization activity of DNA polymerases. Carryover of reagents used for isolation of nucleic acids from clinical specimens can also inhibit amplification reactions. Other causes of false-negative results include target nucleic acid degradation, sample processing errors, thermal cycler malfunction, and in reverse transcription-PCR, failure of the reverse transcription step. A simple approach to detect inhibitors is to add the target nucleic acid to a separate aliquot of the sample after processing. Addition of the external control to a separate reaction, however, doubles the cost of the assay, and the approach may be unworkable if batch sizes are large. Moreover, addition of the control after sample processing is complete cannot detect sporadic false-negative results attributable to failed or inefficient nucleic acid extraction. Internal amplification controls (IACs) that copurify and coamplify with the target nucleic acid are sensitive indicators of loss or degradation of the target during processing and inhibition of amplification and detection. IACs thus provide an accurate way to assess the integrity of all the steps in a nucleic acid amplification assay and are commonly used in in-laboratory-developed and commercially available tests (8–10). IACs should mimic the target sequences as closely as possible. Ideally an IAC contains primer binding sequences identical to the target but a unique internal sequence. This design minimizes the problems associated with primer multiplexing and facilitates differential detection of target and IAC amplicons. The IAC sequence is usually incorporated into a plasmid and cloned by standard techniques of molecular biology. The plasmid can be added directly to the clinical specimens to control for sample-to-sample variability in the subsequent steps in the assay. Internal control RNA can be packaged in MS2 coliphages to protect them against degradation of the RNA control by ubiquitous RNases found in clinical samples (11 ). These armored RNA molecules have been used as effective IACs in a variety of nucleic acid amplification assays for RNA viruses. Normal cellular gene sequences, which are expected to be present in all specimens, have also been used as IACs (12, 13). These endogenous sequences may not accurately reflect amplification of the primary target, however, because of differences in amplification efficiency and relative abundance of the two targets. The scope of the problem is difficult to define because many nucleic acid amplification tests do not include IACs. Reported frequencies of false-negative results in tests that include IACs range widely, depending on the assay and type of specimen. The need to use IACs should be determined on a case-by-case basis, because development and implementation of such controls can be difficult and they can adversely affect assay sensitivity (4 ). If the reaction failure rate is found to be 2% during test verification, it may not be necessary to routinely use an IAC unless the medical consequences of a false-negative result are severe. Universal acceptance of IACs has been hindered by the technical complexity of their construction, the additional costs associated with the use of separate detection systems, and concerns about adverse affects on assay sensitivity as a result of competition with target template. In this issue of Clinical Chemistry, Burggraf and Olgemöller (14 ) describe a novel approach for the design and use of IACs in LightCycler (Roche Applied Science) real-time PCR assays. This approach does not require plasmid construction or use of a separate detection probe. Singlestranded oligonucleotides of 120 nucleotides, containing the sequences for binding of primer and detection of probes, were chemically synthesized with several mismatches in the site for binding of a detection probe. Mismatches in the detection probe-binding region prevented hybridization to the internal control oligonucleotide (ICO) amplicon during fluorescence signal acquisition during real-time PCR. However, the ICO amplicon was detected and easily distinguished from the target amplicon in subsequent melting curve analysis. The authors demonstrated the feasibility of this new approach with LightCycler assays for Mycobacterium tuberculosis complex, hepatitis B virus, herpes simplex virus, and varicella zoster virus. Use of the ICOs did not change the detection limits of these assays. In designing the ICOs, the authors exploited the ability of fluorescence resonance energy transfer (FRET) hybridization probes and the LightCycler to distinguish amplicons based on differences in melting temperature (Tm). Each PCR product–probe complex melts at a characteristic temperature, and with simple hybridization probes, the melting occurs at a characteristic temperature that can be used to distinguish the product from others. A decrease in fluorescence with heating follows the melting of the probe and indicates the Tm of the probe–target duplex. The base mismatches incorporated into the sequences of the IACs that hybridize with the detector probes dramatically reduce the Tm of the detector probe. The detector probe and Editorial

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality Control of Widely Used Therapeutic Recombinant Proteins by a Novel Real-Time PCR Approac

Background: Existence of bacterial host cell DNA contamination in biopharmaceutical products is a potential risk factor for patients receiving these drugs. Hence, the quantity of contamination must be controlled under the regulatory standards. Although different methods such as hybridization assays have been employed to determine DNA impurities, these methods are labor, intensive and rather exp...

متن کامل

Simple technique for internal control of real-time amplification assays.

BACKGROUND In real-time PCR assays, the most accurate way to identify false-negative results, e.g., those caused by PCR inhibitors, is to add to samples an internal control that will be coamplified with the target (e.g., pathogen) DNA. Current internal control procedures, however, which usually involve the introduction of a DNA fragment, are complex, time-consuming, and expensive. METHODS Sin...

متن کامل

Analysis of Herpes Simplex Virus in Suspected Encephalitis, Keratitis and Dermal Infections Using Real- Time PCR

Background & Objectives: Herpes viruses can cause diseases in the clinical range. The virus can cause infection in various body parts, especially eyes and nervous system. The aim of this study was at evaluating  the Real-Time TaqMan probe PCR in diagnosing and monitoring of the patients with suspected HSV infections.Materials & Methods: More than a thousand patients with suspected HSV infection...

متن کامل

Use of bacteriophage MS2 as an internal control in viral reverse transcription-PCR assays.

Diagnostic systems based on reverse transcription (RT)-PCR are widely used for the detection of viral genomes in different human specimens. The application of internal controls (IC) to monitor each step of nucleic acid amplification is necessary to prevent false-negative results due to inhibition or human error. In this study, we designed various real-time RT-PCRs utilizing the coliphage MS2 re...

متن کامل

Validation of Reference Genes for Real Time PCR Normalization in Milk Somatic Cells of Holstein Dairy Cattle

Real time-qPCR is the most reliable method for evaluation of mRNA expression levels. However, to obtain accurate results, selection of suitable reference genes is necessary for normalizing the real-time qPCR data. The aim of this research was to validate the expression stability of three potential reference genes (ACTB, GAPDH and UXT) in milk somatic cells of Holstein dairy cattle under differe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 50 5  شماره 

صفحات  -

تاریخ انتشار 2004