Microbiological contamination of a hemodialysis center water distribution system.

نویسندگان

  • Lilian Bueno Montanari
  • Flávio Garcia Sartori
  • Miguel Jorge de Oliveira Cardoso
  • Samuel Dutra Varo
  • Regina Helena Pires
  • Clarice Queico Fujimura Leite
  • Karina Prince
  • Carlos Henrique Gomes Martins
چکیده

The microbiological monitoring of the water used for hemodialysis is extremely important, especially because of the debilitated immune system of patients suffering from chronic renal insufficiency. To investigate the occurrence and species diversity of bacteria in waters, water samples were collected monthly from a hemodialysis center in upstate São Paulo and tap water samples at the terminal sites of the distribution system was sampled repeatedly (22 times) at each of five points in the distribution system; a further 36 samples were taken from cannulae in 19 hemodialysis machines that were ready for the next patient, four samples from the reuse system and 13 from the water storage system. To identify bacteria, samples were filtered through 0.22 microm-pore membranes; for mycobacteria, 0.45 microm pores were used. Conventional microbiological and molecular methods were used in the analysis. Bacteria were isolated from the distribution system (128 isolates), kidney machine water (43) and reuse system (3). Among these isolates, 32 were Gram-positive rods, 120 Gram-negative rods, 20 Gram-positive cocci and 11 mycobacteria. We propose the continual monitoring of the water supplies in hemodialysis centers and the adoption of effective prophylactic measures that minimize the exposure of these immunodeficient patients to contaminated sources of water.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevent infection linked to the dialysis water in a hemodialysis center in Fez city (Morocco)

BACKGROUND Water treatment systems are a critical variable in dialysis therapy. Rigorous control of hemodialysis water quality is particularly important in order to guarantee a better quality of life of the hemodialysis patients. The objective of the study was to evaluate the chemical, microbiological quality and antimicrobial resistance of bacteria isolated from water and dialysate in a public...

متن کامل

Study on Microbiological Quality of Rural and Urban Drinking Water in Distribution Systems of Ijroud, Zanjan in 2013-2015

Background: Providing safe drinking water has critical importance to human societies. The aim of this study was to investigate microbiological quality of drinking water in distribution system of urban and rural regions of Ijroud, in Zanjan province.   Materials and Methods: In present descriptive study, the microbiological examination of drinking water was conducted in 15 facilities with...

متن کامل

Microbiological Analysis of Hemodialysis Water at the University Teaching Hospital of Yaounde, Cameroon

Rigorous control of the microbiological quality of water in hemodialysis services is important because the immune system of patients with chronic renal failure is weakened. The objective of this study was to determine the microbiological quality of water for hemodialysis in the hemodialysis department of the University Teaching Hospital of Yaoundé in order to improve the disinfection strategy. ...

متن کامل

[The quality of dialysis water].

INTRODUCTION Every week, haemodialysis patients are exposed to approximately 400 l of water used for the production of dialysis fluids which, albeit with the interposition of a semi-permeable artificial membrane, come into direct contact with the bloodstream. It is therefore clearly important to know and monitor the chemical and microbiological purity of dialysis water. METHODS In this review...

متن کامل

Factors that influence microbial contamination of fluids associated with hemodialysis machines.

Studies were conducted on the microbiological quality of fluids associated with different types of dialysis systems located in six dialysis centers and 14 homes. Included were (i) single-pass systems employing either parallel flow (Kiil or Gambro) or capillary cartridge dialyzers and (ii) recirculating single-pass and batch recirculating systems using coil dialyzers. Microbiological assays were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista do Instituto de Medicina Tropical de Sao Paulo

دوره 51 1  شماره 

صفحات  -

تاریخ انتشار 2009