Improved determination of cytochrome b5 in human erythrocytes.
نویسندگان
چکیده
A sensitive, precise enzymic/spectrophotometric method for determining cytochrome b5 in small amounts of blood is described. Mean values for healthy individuals, ages 20 to 70 years, were 0.26 (SD 0.03) mumol per liter of erythrocytes or 0.87 (SD 0.14) nmol per gram of hemoglobin. We believe the assay is preferable to methods described hitherto, primarily because of its high sensitivity.
منابع مشابه
Membrane-bound cytochrome b5 reductase (methemoglobin reductase) in human erythrocytes. Study in normal and methemoglobinemic subjects.
In this study we present evidence that in human erythrocytes NADH-cytochrome b5 reductase (methemoglobin reductase) is not only soluble but also tightly bound to the membrane. The membrane methemoglobin reductase-like activity is unmasked by Triton X-100 treatment, and represents about half of the total activity in the erythrocytes. Like the amphiphilic microsomal-bound cytochrome b5 reductase,...
متن کاملCytochrome b5 reductase activity in erythrocytes and leukocytes as related to sex and age.
We measured cytochrome b5 reductase (EC 1.6.2.2) activity in erythrocytes and leukocytes from subjects of both sexes ranging in age from neonate to adulthood, all either apparently healthy or without hematologic disorders. The activities were determined spectrophotometrically (J. Lab. Clin. Med. 72: 339-344, 1968). Within-run precision (CV) of the reductase determination was 6.4% and 3.7% for e...
متن کاملEffects of hemolysate concentration, ionic strength and cytochrome b5 concentration on the rate of methemoglobin reduction in hemolysates of human erythrocytes.
An assay for determining the rate of methemoglobin reduction in hemolysates of human erythrocytes has been developed. The rates obtained by this assay, when corrected for dilution, are comparable to those obtained with intact cells. Increased ionic strength inhibits the reaction, whereas EDTA increases the rate of reduction. The rate with NADPH as electron donor is 65-70% of the rate with NADH....
متن کاملAutomated determination of red cell methaemoglobin reductase activity by a continuous-flow system for screening hereditary methaemoglobinaemia.
A flow diagram for the automated determination of ferricyanide reductase activity in red blood cells was prepared in the modules from AutoAnalyzer AA I (Technicon Instruments Inc). Ferricyanide reductase assay can be substituted for assay of cytochrome b5 reductase (EC 1.6.2.2), which plays a major role in reducing methaemoglobin in erythrocytes, and is defective specifically in the erythrocyte...
متن کاملAlteration of NADH-diaphorase and cytochrome b5 reductase activities of erythrocytes, platelets, and leucocytes in hereditary methaemoglobinaemia with and without mental retardation.
NADH-diaphorase and cytochrome b5 reductase activities of platelets and leucocytes, as well as erythrocytes, were found to be deficient in a patient with hereditary methaemoglobinaemia associated with moderate mental retardation and non-progressive neurological disturbance, in which hyperactive reflexes and involuntary movements were notable. In another methaemoglobinaemic patient with no menta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 30 8 شماره
صفحات -
تاریخ انتشار 1984