Transcatheter closure of small ductus arteriosus with amplatzer vascular plug
نویسندگان
چکیده
PURPOSE The purpose of this study was to share our experience of transcatheter closure of small patent ductus arteriosus (PDA) by using an Amplatzer vascular plug (AVP). METHODS We reviewed the medical records of 20 patients who underwent transcatheter closure at Samsung Medical Center and Sejong General Hospital from January 2008 to August 2012. The size and shape of the PDAs were evaluated by performing angiograms, and the PDA size and the AVP devices size were compared. RESULTS The mean age of the patients was 54.9±45.7 months old. The PDAs were of type C (n=5), type D (n=12), and type E (n=3). The mean pulmonary end diameter of the PDA was 1.7±0.6 mm, and the aortic end diameter was 3.6±1.4 mm. The mean length was 7.3±1.8 mm. We used 3 types of AVP devices: AVP I (n=5), AVP II (n=7), and AVP IV (n=8). The ratio of AVP size to the pulmonary end diameter was 3.37±1.64, and AVP size/aortic end ratio was 1.72±0.97. The aortic end diameter was significantly larger in those cases repaired with AVP II than in the others (P=0.002). The AVP size did not significantly correlate with the PDA size, but did correlate with smaller ratio of AVP size to aortic end diameter (1.10±0.31, P=0.032). CONCLUSION Transcatheter closure of small PDA with AVP devices yielded satisfactory outcome. AVP II was equally effective with smaller size of device, compared to others.
منابع مشابه
Use of an Amplatzer Vascular Plug to occlude a tubular type of patent ductus arteriosus
Patent ductus arteriosus (PDA) is a common congenital heart defect. All PDAs, regardless of size or degree of symptoms, require occlusion. Transcatheter PDA occlusion features fewer complications than trans-thoracic closure. It is also more cost-effective and has an excellent occlusion rate. Therefore, transcatheter PDA occlusion is accepted as the standard treatment option for PDA. However, tu...
متن کاملUse of the amplatzer vascular plug II device to occlude different types of patent ductus arteriosus in pediatric patients.
INTRODUCTION Transcatheter patent ductus arteriosus (PDA) closure is difficult in small patients in part due to the diverse PDA morphology. We describe a multicenter pediatric experience using the Amplatzer Vascular Plug II device (AVP II) to occlude PDA. METHODS All patients undergoing transcatheter closure of PDA with AVP II from April 2008 until May 2012 were included. Clinical, angiograph...
متن کاملPercutaneous embolization of a caroticoazygous fistula with the Amplatzer Vascular Plug 1.
We present the case of a five-year-old boy with a caroticoazygous fistula, which is an extremely rare congenital vascular malformation. The patient also had patent ductus arteriosus, a common cause of continuous murmur. The murmur continued despite successful coil embolization of the ductus. Repeated catheter-angiography revealed a large caroticoazygous fistula. The fistula was successfully emb...
متن کاملTranscatheter closure of persistent ductus arteriosus in infants using the Amplatzer duct occluder.
AIM To evaluate whether transcatheter closure with the Amplatzer duct occluder offers an alternative to surgical treatment in infants with a persistent ductus arteriosus. METHODS 12 patients under 1 year of age (age 1-11 months, body weight 2.6-8.7 kg) with clinical and echocardiographic findings of a significant duct were considered for transcatheter closure with the Amplatzer occluder. The ...
متن کاملTranscatheter Closure of Patent Ductus Arteriosus Using the Amplatzer Duct Occluder.
The Amplatzer duct occluder (ADO) (AGA Medical Corp., Golden Valley, MN) is designed to meet criteria for an optimal transcatheter technique for closure of a patent ductus arteriosus. It was developed as an alternative to surgical closure and other interventional techniques. It is not technically complex, allows controlled deployment, is retrievable and repositionable, and has a low risk of emb...
متن کامل