A Transient Current Based Transmission line Protection Using Neuro-Wavelet Approach in the Presence of Static Var Compensator
نویسنده
چکیده
The SVC (Static Var Compensator) based on voltage source converter (VSC) is used for voltage regulation in transmission and distribution system. The SVC can rapidly supply dynamic VARs required during system faults for voltage support. The apparent impedance is influenced by the reactive power injected or absorbed by the SVC, which will result in the under reaching or over reaching of distance relay. This paper presents simulation results of the application of distance relays for the protection of transmission systems employing flexible alternating current transmission controllers such as SVC. The complete digital simulation of the Static Var Compensator within a transmission system is performed in the MATLAB/Simulink environment using the Power System Block set (PSB). This paper presents an efficient method based on wavelet transforms, fault detection, classification and location using ANN technique which is almost independent of fault impedance, fault distance and fault inception angle .
منابع مشابه
Fast Transient Hybrid Neuro Fuzzy Controller for STATCOM During Unbalanced Voltage Sags
A static synchronous compensator (STATCOM) is generally used to regulate voltage and improve transient stability in transmission and distribution networks. This is achieved by controlling reactive power exchange between STATCOM and the grid. Unbalanced sags are the most common type of voltage sags in distribution networks. A static synchronous compensator (STATCOM) is generally used to maintain...
متن کاملImpedance-Based Out-of-Step Protection of Generator in the Presence of STATCOM
This paper presents a novel impedance-based approach for out-of-step (OOS) protection of a synchronous generator. The most popular and commonly used approaches for detecting OOS conditions are based on the measurement of positive sequence impedance at relay location. However, FACTS devices change the measured impedance value and thus disrupt the performance of impedance-based relay function. In...
متن کاملFault Analysis of Double Line Transmission System with STATCOM Controller Using Neuro-Wavelet Based Technique
The STATCOM (Synchronous Static Compensator) based on voltage source converter (VSC) is used for voltage regulation in transmission and distribution systems. The STATCOM can rapidly supply dynamic VARs required during system faults for voltage support. The apparent impedance is influenced by the reactive power injected or absorbed by the STATCOM, which will result in the under reaching or over ...
متن کاملModified Impedance-Based OOS Protection Based on On-Line Thévenin Equivalent Estimation
In this paper, a novel approach based on the Thévenin tracing is presented to modified conventional impedance-based out-of-step (OOS) protection. In conventional approach, the OOS detection is done by measuring positive sequence impedance. However, the measured impedance may be change due to different factors such as capacitor bank switching and reactive power compensators that it can cause the...
متن کاملFACTS Devices Allocation to Congestion Alleviation Incorporating Voltage Dependence of Loads
This paper presents a novel optimization based methodology to allocate Flexible AC Transmission Systems (FACTS) devices in an attempt to improve the previously mentioned researches in this field. Static voltage stability enhancement, voltage profile improvement, line congestion alleviation, and FACTS devices investment cost reduction, have been considered, simultaneously, as objective funct...