Detection of Colorectal Serrated Polyps by Stool DNA Testing: Comparison with Fecal Immunochemical Testing for Occult Blood (FIT)

نویسندگان

  • Russell I. Heigh
  • Tracy C. Yab
  • William R. Taylor
  • Fareeda T. N. Hussain
  • Thomas C. Smyrk
  • Douglas W. Mahoney
  • Michael J. Domanico
  • Barry M. Berger
  • Graham P. Lidgard
  • David A. Ahlquist
چکیده

OBJECTIVES Precursors to 1/3 of colorectal cancer (CRC), serrated polyps have been under-detected by screening due to their inconspicuous, non-hemorrhagic, and proximal nature. A new multi-target stool DNA test (multi-target sDNA) shows high sensitivity for both CRC and advanced adenomas. Screen detection of serrated polyps by this approach requires further validation. We sought to assess and compare noninvasive detection of sessile serrated polyps (SSP) ≥ 1 cm by sDNA and an occult blood fecal immunochemical test (FIT). METHODS In a blinded prospective study, a single stool sample used for both tests was collected from 456 asymptomatic adults prior to screening or surveillance colonoscopy (criterion standard). All 29 patients with SSP ≥ 1 cm were included as cases and all 232 with no neoplastic findings as controls. Buffered stool samples were processed and frozen on receipt; Exact Sciences performed sDNA in batches using optimized analytical methods. The sDNA multi-marker panel targets methylated BMP3 (mBMP3) and NDRG4, mutant KRAS, β-actin, and hemoglobin. FIT (Polymedco OC-FIT Check) was performed in separate lab ≤ 2 days post defecation and evaluated at cutoffs of 50 (FIT-50) and 100 ng/ml (FIT-100). RESULTS MEDIAN AGES: cases 61 (range 57-77), controls 62 (52-70), p = NS. Women comprised 59% and 51%, p = NS, respectively. SSP median size was 1.2 cm (1-3 cm), 93% were proximal, and 64% had synchronous diminutive polyps. Among multi-target sDNA markers, mBMP3 proved highly discriminant for detection of SSP ≥ 1 cm (AUC = 0.87, p<0.00001); other DNA markers provided no incremental sensitivity. Hemoglobin alone showed no discrimination (AUC = 0.50, p = NS). At matched specificities, detection of SSP ≥ 1 cm by stool mBMP3 was significantly greater than by FIT-50 (66% vs 10%, p = 0.0003) or FIT-100 (63% vs 0%, p<0.0001). CONCLUSIONS In a screening and surveillance setting, SSP ≥ 1 cm can be detected noninvasively by stool assay of exfoliated DNA markers, especially mBMP3. FIT appears to have no value in SSP detection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multitarget stool DNA testing for colorectal-cancer screening.

BACKGROUND An accurate, noninvasive test could improve the effectiveness of colorectal-cancer screening. METHODS We compared a noninvasive, multitarget stool DNA test with a fecal immunochemical test (FIT) in persons at average risk for colorectal cancer. The DNA test includes quantitative molecular assays for KRAS mutations, aberrant NDRG4 and BMP3 methylation, and β-actin, plus a hemoglobin...

متن کامل

Comparison of a brush-sampling fecal immunochemical test for hemoglobin with a sensitive guaiac-based fecal occult blood test in detection of colorectal neoplasia.

BACKGROUND Fecal immunochemical tests (FIT) are an advanced fecal occult blood test (FOBT) technology that reduces barriers to population screening by simplifying the logistics of stool-sampling. The current study was conducted to undertake a paired comparison of a sensitive guaiac FOBT (GFOBT; Hemoccult II Sensa, Beckman Coulter, Fullerton, CA) with a brush-sampling FIT (InSure; Enterix, North...

متن کامل

Fecal occult blood versus DNA testing: indirect comparison in a colorectal cancer screening population

BACKGROUND A multitarget stool DNA test (MSDT) that showed higher sensitivity but lower specificity than a fecal immunochemical test (FIT) for hemoglobin in one recent study from the US and Canada, is increasingly used for colorectal cancer (CRC) screening, despite its ~20-fold higher costs compared to FITs. We aimed to assess diagnostic performance of a quantitative FIT in an independent study...

متن کامل

Colorectal Cancer Screening: Tests, Strategies, and Perspectives

Screening has a central role in colorectal cancer (CRC) control. Different screening tests are effective in reducing CRC-specific mortality. Influence on cancer incidence depends on test sensitivity for pre-malignant lesions, ranging from almost no influence for guaiac-based fecal occult blood testing (gFOBT) to an estimated reduction of 66-90% for colonoscopy. Screening tests detect lesions in...

متن کامل

A comparison of three stool tests for colorectal cancer screening.

The annual guaiac or immunochemical fecal occult blood test (FOBT) is one of the five colorectal cancer (CRC) screening regimens recommended by the American Cancer Society (Smith, Cokkinides, & Eyre, 2005). Stool-based deoxyribonucleic acid (DNA) testing for CRC is considered a promising technology (Smith, Cokkinides, & Eyre, 2003). Numerous features of three noninvasive stool tests for CRC are...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014