Independent Component Analysis for Fetal Heart Rate Detection Using Photoplethysmography

نویسندگان

  • Malek M. A. Harbawi
  • Othman O. Khalifa
چکیده

Photoplethysmography (PPG) is an optoelectronic technique for measuring and recording changes in the volume of body parts. These changes are associated with each heart beat and acquired by pulse oximetry. Fetal heart rate (FHR) monitoring using PPG is a challenging task since the acquired signals present the pattern of both fetal and maternal hearts. The effect of maternal component, noise and artifacts on fetal component makes the separation of FHR very difficult. In this paper, we study the applicability of independent component analysis (lCA) to FHR detection using PPG. The study was conducted using emulated signals to mimic the pulsation nature of both maternal and fetal hearts. The outcome of this experiment shows encouraging results in terms of the extraction ability oflCA, which can perform well even when fetal-to-maternal signal-to-noise ratio (SIY~) drops to -276 dB.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A PCA/ICA based Fetal ECG Extraction from Mother Abdominal Recordings by Means of a Novel Data-driven Approach to Fetal ECG Quality Assessment

Background: Fetal electrocardiography is a developing field that provides valuable information on the fetal health during pregnancy. By early diagnosis and treatment of fetal heart problems, more survival chance is given to the infant.Objective: Here, we extract fetal ECG from maternal abdominal recordings and detect R-peaks in order to recognize fetal heart rate. On the next step, we find a be...

متن کامل

Assessment of Effects of Visually-Induced Motion Sickness Using Physiological Index Obtained from Photoplethysmography

A human watching a swaying image displayed on a wide-field display or screen sometimes suffers from visually-induced motion sickness (VIMS) that causes symptoms related to the autonomic nervous system such as nausea, vomiting, and dizziness. The previous study indicated that the maximum cross-correlation coefficient (ρmax) between blood pressure and heart rate whose frequency components are lim...

متن کامل

Heart Rate Detection from Photoplethysmography- A Comparative Study

Photoplethysmography is a simple way for heart rate detection. However due to low level of detected signal, easily prone to motion artifacts and noise. In this paper DWT method is used to reduce the effect of noise, thereby calculate the heart rate. A comparative study of detecting heart rate using different mother wavelet is also discussed. Keywords— Heart beats, ECG, Photoplethysmography, Pea...

متن کامل

Electrocardiography versus photoplethysmography in assessment of maternal heart rate variability during labor

PURPOSE Evaluation of maternal heart rate (MHR) variability provides useful information on the maternal-fetal clinical state. Electrocardiography (ECG) is the most accurate method to monitor MHR but it may not always be available, and pulse oximetry using photoplethysmography (PPG) can be an alternative. In this study we compared ECG and PPG signals, obtained with conventional fetal monitors, t...

متن کامل

Multi - Modal Heart - Beat Estimation On an iPhone by Narges Norouzi

Multi-Modal Heart-Beat Estimation On an iPhone Narges Norouzi Master of Applied Science Graduate Department of Electrical and Computer Engineering University of Toronto 2014 Current generation smartphone video cameras and microphones enable photoplethysmography (PPG) and phonocardiography (PCG) acquisition. In this thesis, I utilized the iPhone microphone and camera to measure heart rate. We de...

متن کامل