Performance improvement of small gamma camera using NaI(Tl) plate and position sensitive photo-multiplier tubes.
نویسندگان
چکیده
The purpose of this study was to improve the performance of a small gamma camera, utilizing a NaI(Tl) plate and a 5" position sensitive PMT. We attempted to build a NaI(Tl) plate crystal system which retained all its advantages, while at the same time integrating some of the advantages inherent in an array-type scintillation crystal system. Flood images were obtained with a lead hole mask, and position mapping was performed by detecting hole positions in the flood image. Energy calibration was performed using the energy spectra obtained from each hole position. Flood correction was performed using a uniformity correction table containing the relative efficiency of each image element. The spatial resolution was improved about 16% after correction at the centre field of view. Resolution deterioration at the outer field of view (OFOV) was considerably ameliorated, from 6.7 mm to 3.2 mm after correction. The sensitivity at the OFOV was also increased after correction, from 0.7 cps microCi(-1) to 2.0 cps microCi(-1). The correction also improved uniformity, from 5.2% to 2.1%, and linearity, from 0.5 mm to 0 mm. The results of this study indicate that the revised correction method can be employed to considerably improve the performance of a small gamma camera using a NaI(Tl) plate-type crystal. This method also provides high spatial resolution and linearity, like array-type crystals do, while retaining the specific advantages of plate-type crystals.
منابع مشابه
Comparative assessment of the accuracy of maximum likelihood and correlated signal enhancement algorithm positioning methods in gamma camera with large square photomultiplier tubes
Introduction: The gamma cameras, based on scintillation crystal followed by an array of photomultiplier tubes (PMTs), play a crucial role in nuclear medicine. The use of square PMTs provides the minimum dead zones in the camera. The camera with square PMTs also reduces the number of PMTs relative to the detection area. Introduction of a positioning algorithm to improve the spat...
متن کاملA Study on the Optimization of Optical Guide of Gamma Camera Detector
An optical guide, which is a light guide located between NaI(Tl) scintillation-crystal and array of photo-multiplier tubes (PMTs) in the gamma camera detector system, is an essential component to deliver the spatial information recorded in scintillator to the PMTs. Without the optical guide, the spatial information within the range of a single PMT could not be obtained. For the design of the op...
متن کاملGamma Ray Imaging of Small Animals Using Position-Sensitive Photomultiplier Tubes
This thesis is an interdisciplinary investigation of small animals consisting of two parts. First, a comparison of NaI(Tl) and CsI(Tl) pixilated scintillating crystals will be presented based on results of resolution tests performed using 5 " diameter Hamamatsu 5800 PSPMTs. Second, application of the gamma ray detectors will be assessed using a biological model. The biological model chosen to a...
متن کاملEvaluation of Breast Tumor Detectability With Two Dedicated, Compact Scintillation Cameras
As part of the development of dedicated scintillation cameras for breast imaging, we compared the performances of two dedicated cameras with a standard clinical camera (Siemens Orbiter). One dedicated camera was based on a single position-sensitive photomultiplier tube (PSPMT) coupled to a 6 cm by 6 cm by 6 mm NaI(Tl) crystal. The other (LumaGem) was based on multiple-PSPMTs coupled to a 2 mm 2...
متن کاملDetermination of the dead-time losses in NaI(Tl) gamma-ray spectrometer
The 12 NaI(Tl)-detector gamma-ray spectrometry system (GSS) “Romashka”[1,2] has recently been equipped with a new computer controlled HVSys 16 channel high-voltage power supply with preselected single channel polarity [3] (Fig.1). In order to do some preliminary checks of the GSS chains’ characteristics, a single channel gamma-spectrometry tract was commissioned. It was consist of a single Roma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 49 21 شماره
صفحات -
تاریخ انتشار 2004