Size of the pores created by an electric pulse: microsecond vs millisecond pulses.

نویسندگان

  • Gintautas Saulis
  • Rita Saulė
چکیده

Here, the sizes of the pores created by square-wave electric pulses with the duration of 100 μs and 2 ms are compared for pulses with the amplitudes close to the threshold of electroporation. Experiments were carried out with three types of cells: mouse hepatoma MH-22A cells, Chinese hamster ovary (CHO) cells, and human erythrocytes. In the case of a short pulse (square-wave with the duration of 100 μs or exponential with the time constant of 22 μs), in the large portion (30-60%) of electroporated (permeable to potassium ions) cells, an electric pulse created only the pores, which were smaller than the molecule of bleomycin (molecular mass of 1450 Da, r≈0.8 nm) or sucrose (molecular mass of 342.3 Da, radius-0.44-0.52 nm). In the case of a long 2-ms duration pulse, in almost all cells, which were electroporated, there were the pores larger than the molecules of bleomycin and/or sucrose. Kinetics of pore resealing depended on the pulse duration and was faster after the shorter pulse. After a short 100-μs duration pulse, the disappearance of the pores permeable to bleomycin was completed after 6-7 min at 24-26°C, while after a long 2-ms duration pulse, this process was slower and lasted 15-20 min. Thus, it can be concluded that a short 100-μs duration pulse created smaller pores than the longer 2-ms duration pulse. This could be attributed to the time inadequacy for pores to grow and expand during the pulse, in the case of short pulses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Quantitative Study of the Effect of Electroporation on the Electropermeability and Cell Survival

Introduction: Electroporation is a practical technique used to transport the molecules across the cell membrane. The utilization of fluorescent molecules is the method widely used to evaluate the electropermeability of cell membrane as a result of pulse application. It is also possible to use mathematical methods to predict the changes caused in cell electropermeability as a result of the chang...

متن کامل

Induction of Localized Hyperthermia by Millisecond Laser Pulses in the Presence of Gold-Gold Sulphide Nanoparticles in a Phantom

Introduction Application of near-infrared absorbing nanostructures can induce hyperthermia, in addition to providing more efficient  photothermal effects. Gold-gold sulfide (GGS) is considered as one of these nanostructures. This study was performed on a tissue-equivalent optical-thermal phantom to determine the temperature profile in the presence and absence of GGS and millisecond pulses of a ...

متن کامل

A Search for Giant Pulses from Millisecond Pulsars

We have searched for microsecond-timescale broadband emission from a sample of eighteen millisecond pulsars. Our study places strong limits on such emission from several millisecond pulsars and shows that it is only present in a small subset of millisecond pulsars. Giant pulses of up to 64 times the mean pulse energy were detected from PSR J1823−3021A in the globular cluster NGC 6624. In contra...

متن کامل

Relative Electropermeability and Electric Pulse Effectiveness in Human Breast Adenocarcinoma: An in vitro Study

Objective(s) This study was carried out in order to evaluate the effects of electrochemotherapy, electrical pulses and chemotherapeutic drugs on the killing of cancerous cells and their probable synergistic effects. Materials and Methods Electrochemotherapy treatments conducted on MCF-7 cell line derived from human breast adenocarcinoma tumor using four chemotherapeutic drugs including bleom...

متن کامل

Effect of Cell Size and Shape on Electric Field Threshold and Critical Transmembrane Voltage for Electroporation

Introduction:  Electroporation  is  a  technique  for  increasing  the  permeability  of  the  cell  membrane  to  otherwise  non-permeate  molecules  due  to  an  external  electric  field.  This  permeability  enhancement  is  detectable if the induced transmembrane voltage becomes greater than a critical value which depends on the  pulse  strength  threshold.  In  this  study,  the  variabil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biochimica et biophysica acta

دوره 1818 12  شماره 

صفحات  -

تاریخ انتشار 2012