Automated Analysis of Multi Site MRI Phantom Data for the NIHPD Project
نویسندگان
چکیده
In large multi-center studies it is important to quantify data variations due to differences between sites and over time. Here we investigate inter-site variability in signal to noise ratio (SNR), percent integral uniformity (PIU), width and height using the American College of Radiology (ACR) phantom scans from the NIHPD project. Longitudinal variations are also analyzed. All measurements are fully automated. Our results show that the mean SNR, PIU and the 2 metric values were statistically different across sites. The maximum mean difference in diameter across sites was 2 mm (1.1%), and the maximum mean difference in height was 2.5 mm (1.7%). Over time, an average drift of 0.4 mm per year was observed for the diameter while a drift of 0.5 mm per year was observed for the height. Trends observed over time often depended not only on site, but also on modality and scanner manufacturer.
منابع مشابه
Reliability in multi-site structural MRI studies: effects of gradient non-linearity correction on phantom and human data.
Longitudinal and multi-site clinical studies create the imperative to characterize and correct technological sources of variance that limit image reproducibility in high-resolution structural MRI studies, thus facilitating precise, quantitative, platform-independent, multi-site evaluation. In this work, we investigated the effects that imaging gradient non-linearity have on reproducibility of m...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملReal-Time Building Information Modeling (BIM) Synchronization Using Radio Frequency Identification Technology and Cloud Computing System
The online observation of a construction site and processes bears significant advantage to all business sector. BIM is the combination of a 3D model of the project and a project-planning program which improves the project planning model by up to 6D (Adding Time, Cost and Material Information dimensions to the model). RFID technology is an appropriate information synchronization tool between the...
متن کاملQuantification of accuracy and precision of multi-center DTI measurements: A diffusion phantom and human brain study
The inter-site and intra-site variability of system performance of MRI scanners (due to site-dependent and time-variant variations) can have significant adverse effects on the integration of multi-center DTI data. Measurement errors in accuracy and precision of each acquisition determine both the inter-site and intra-site variability. In this study, multiple scans of an identical isotropic diff...
متن کاملEvaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel Dosimetry
Introduction: The purpose of this work was to study the ability of MRI normoxic polymer gel dosimetry for evaluating the dose distribution in HDR brachytherapy of esophagial cancer at Imam Reza brachytherapy center (Mashhad, Iran). Materials and Methods: Initially, 2liters of normoxic gel (MAGIC) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention
دوره 9 Pt 2 شماره
صفحات -
تاریخ انتشار 2006