Method modification of the Legipid® Legionella fast detection test kit.

نویسندگان

  • Guillermo Rodríguez Albalat
  • Begoña Bedrina Broch
  • Marisa Jiménez Bono
چکیده

Legipid(®) Legionella Fast Detection is a test based on combined magnetic immunocapture and enzyme-immunoassay (CEIA) for the detection of Legionella in water. The test is based on the use of anti-Legionella antibodies immobilized on magnetic microspheres. Target microorganism is preconcentrated by filtration. Immunomagnetic analysis is applied on these preconcentrated water samples in a final test portion of 9 mL. The test kit was certified by the AOAC Research Institute as Performance Tested Method(SM) (PTM) No. 111101 in a PTM validation which certifies the performance claims of the test method in comparison to the ISO reference method 11731-1998 and the revision 11731-2004 "Water Quality: Detection and Enumeration of Legionella pneumophila" in potable water, industrial water, and waste water. The modification of this test kit has been approved. The modification includes increasing the target analyte from L. pneumophila to Legionella species and adding an optical reader to the test method. In this study, 71 strains of Legionella spp. other than L. pneumophila were tested to determine its reactivity with the kit based on CEIA. All the strains of Legionella spp. tested by the CEIA test were confirmed positive by reference standard method ISO 11731. This test (PTM 111101) has been modified to include a final optical reading. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method. Two water matrixes were analyzed. Results show no statistically detectable difference between the test method and the reference culture method for the enumeration of Legionella spp. The relative level of detection was 93 CFU/volume examined (LOD50). For optical reading, the LOD was 40 CFU/volume examined and the LOQ was 60 CFU/volume examined. Results showed that the test Legipid Legionella Fast Detection is equivalent to the reference culture method for the enumeration of Legionella spp.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Oxoid Xpect Legionella test kit for detection of Legionella pneumophila serogroup 1 antigen in urine.

We evaluated a new immunochromatographic assay (Oxoid Xpect Legionella test kit) for the ability to detect Legionella pneumophila serogroup 1 antigen in urine. The results were compared with those obtained with the Binax NOW urinary antigen test by following the manufacturers' instructions. The sensitivities and specificities were estimated to be 89 and 100%, respectively, for the Oxoid Xpect L...

متن کامل

Laboratory Diagnosis of Pneumonia by Detection of Urinary Antigen Test of Legionella Pnuemophilia

Background and Aims: Legionnaires’ disease is seen in sporadic and epidemic form. The most prevalent cause is Legionella pnuemophilia (L.pneumophila), which produces a severe disease in vulnerable individuals with a high fatality rate. This study was conducted due to the wide and universal distribution of the Legionnaires’ disease, lack of conventional and accessible diagnostic meth...

متن کامل

مقایسه حساسیت پرایمرهای مختلف اختصاصی ناحیه  16srDNAدر شناسایی گونه‌های باکتری لژیونلا در نمونه‌های آبی

Background and Objectives: Legionella are gram-negative bacteria widely dispersed in natural and man-made water sources. Some Legionella species are pathogenic and could cause respiratory infections. Cultivation technique is the conventional method for the detection of Legionella spp. in aquatic samples. However, the method has low sensitivity and require prolonged incubation period. Theref...

متن کامل

Evaluation of the Merifluor-Legionella immunofluorescent reagent for identifying and detecting 21 Legionella species.

We evaluated a 33-valent polyclonal indirect immunofluorescent-reagent kit (Merifluor-Legionella; Meridian Diagnostics Inc., Cincinnati, Ohio) made for the detection of Legionella species by testing bacterial isolates, seeded sputum, and negative sputum samples. Use of the reagent according to the directions of the manufacturer gave false-negative staining of homologous culture isolates due to ...

متن کامل

Evaluation of the Binax and Biotest urinary antigen kits for detection of Legionnaires' disease due to multiple serogroups and species of Legionella.

The Binax and the Biotest urinary antigen kits for the detection of Legionnaires' disease caused by organisms other than Legionella pneumophila were compared by testing 45 urine samples from non-Legionella pneumophila serogroup 1 patients previously positive in a broad-spectrum enzyme-linked immunosorbent assay (ELISA). Eighteen were positive with the Binax kit, and 13 were positive with the Bi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of AOAC International

دوره 97 5  شماره 

صفحات  -

تاریخ انتشار 2014