Secondary Electron Trajectories in Scanning Tunneling Microscopy
نویسندگان
چکیده
The recently developed technique Scanning Tunneling Microscopy in the Field Emission regime (STM FE) is based on the Russell Young's topografiner technology [1]. The set-up is a no contacting device consisting of a sharp tip approached vertically to a conducting surface at variable distances and biased with a small voltage with respect to the surface (Figure 1). The system builds a junction across which electrons can be transferred from the tip apex to the surface by direct quantum mechanical tunneling if the distance is in the sub nanometer region. In this case the surface topography can be imaged with atomic spatial resolution using the STM technique. In the STM FE mode, the distance between tip and collector is increased and the current is dominated by electrons emitted from the tip into the vacuum region via electric field assisted tunneling. In the experiment, secondary electrons carrying chemical and magnetic information are produced via diverse mechanisms on the surface of the sample and form a cloud in the vicinity around the interaction region in a macroscopic environment. Some of them are attracted by an electric potential to the entrance of a lens system designed for focusing the electrons into a counter and a Mott detector. The imaging of the sample with a resolution in the nanoscale depends on the amount of secondary electrons that effectively reach the detectors. We use COMSOL Multiphysics® to optimize the electrostatic and geometric parameters by calculating the trajectories of the secondary electrons from the sample to the final position on the detectors. The set of results achieved on the physical characterization of the instrument refers to a situation where a nanoscale quantum process, comprising field emission, secondary electron production and electron transport in the presence of strongest electric fields is shown to couple efficiently to a macroscopic environment. An accurate modeling of this multiscale process requires the solution of the Laplace and movement equations in two separate subsystems with different space scales. In the first component, the system consists of a tungsten tip in front of a silicon surface in a subspace of some hundreds of nanometers [2]. In the second component, the geometry is generated by importing a simplified version of the CAD-construction files of the instrument (in a scale of centimeters) (Figure 2). In both cases the electrostatic problem is solved using the AC/DC Module and the trajectories of the electrons are calculated with the Particle Tracing Module. For coupling the two simulations, in analogy to the model "Syngas Combustion in a Round-Jet Burner" (Model Library), the final positions and velocities on the walls of the first Component are used as initial values in the second Component (Figure 3). Most of the calculations are performed on a cluster. First results shown that only a few electrons can escape from the interaction region if their energies are about 70 eV. From the escaped electrons, a 10% can reach the Mott detector (Figure 4).
منابع مشابه
Scanning tunneling microscope study of charge-density-wave modulations in NbTe4
The room-temperature modulated structure of NbTe4 was studied by means of scanning tunneling microscopy. In addition to a relatively weak image of the average structure and stronger contrast from the incommensurate modulation, contributions from domains of nanometer sizes were detected, which appeared with variable amplitudes. The existence of secondary modulation displacements associated with ...
متن کاملDopant Profiling on 4H Silicon Carbide P+N Junction by Scanning Probe and Secondary Electron Microscopy
The availability of two-dimensional (2-D) dopant profiling techniques to Silicon Carbide (SiC) pn junction is discussed. We compared the results of scanning capacitance microscopy (SCM), scanning spreading resistance microscopy (SSRM), and secondary electron microscopy (SEM), where the cross-sections of a SiC wafer with n-type epi-layers and highly-doped p and n regions were used. The SSRM curr...
متن کاملSpin-polarized quantum confinement in nanostructures: Scanning tunneling microscopy
Experimental investigations of spin-polarized electron confinement in nanostructures by scanning tunneling microscopy (STM) and scanning tunneling spectroscopy (STS) are reviewed. To appreciate the experimental results on the electronic level, the physical basis of STM is elucidated with special emphasis on the correlation between differential conductance, as measured by STS, and the electron d...
متن کاملThirty per cent contrast in secondary-electron imaging by scanning field-emission microscopy
We perform scanning tunnelling microscopy (STM) in a regime where primary electrons are field-emitted from the tip and excite secondary electrons out of the target-the scanning field-emission microscopy regime (SFM). In the SFM mode, a secondary-electron contrast as high as 30% is observed when imaging a monoatomic step between a clean W(110)- and an Fe-covered W(110)-terrace. This is a figure ...