Novel Luminex Assay for Telomere Repeat Mass Does Not Show Well Position Effects Like qPCR

نویسندگان

  • Muhammad G Kibriya
  • Farzana Jasmine
  • Shantanu Roy
  • Habibul Ahsan
  • Brandon L Pierce
چکیده

Telomere length is a potential biomarker of aging and risk for age-related diseases. For measurement of relative telomere repeat mass (TRM), qPCR is typically used primarily due to its low cost and low DNA input. But the position of the sample on a plate often impacts the qPCR-based TRM measurement. Recently we developed a novel, probe-based Luminex assay for TRM that requires ~50ng DNA and involves no DNA amplification. Here we report, for the first time, a comparison among TRM measurements obtained from (a) two singleplex qPCR assays (using two different primer sets), (b) a multiplex qPCR assay, and (c) our novel Luminex assay. Our comparison is focused on characterizing the effects of sample positioning on TRM measurement. For qPCR, DNA samples from two individuals (K and F) were placed in 48 wells of a 96-well plate. For each singleplex qPCR assay, we used two plates (one for Telomere and one for Reference gene). For the multiplex qPCR and the Luminex assay, the telomere and the reference genes were assayed from the same well. The coefficient of variation (CV) of the TRM for Luminex (7.2 to 8.4%) was consistently lower than singleplex qPCR (11.4 to 14.9%) and multiplex qPCR (19.7 to 24.3%). In all three qPCR assays the DNA samples in the left- and right-most columns showed significantly lower TRM than the samples towards the center, which was not the case for the Luminex assay (p = 0.83). For singleplex qPCR, 30.5% of the variation in TL was explained by column-to-column variation and 0.82 to 27.9% was explained by sample-to-sample variation. In contrast, only 5.8% of the variation in TRM for the Luminex assay was explained by column-to column variation and 50.4% was explained by sample-to-sample variation. Our novel Luminex assay for TRM had good precision and did not show the well position effects of the sample that were seen in all three of the qPCR assays that were tested.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of telomere length: a new assay using QuantiGene chemistry on a Luminex platform.

BACKGROUND Telomeres are tandem repeats of sequences present at the end of the chromosomes that maintain chromosomal integrity. After repeated cell division, telomeres shorten to a critical level, triggering replicative senescence or apoptosis, which is a key determinant of cellular aging. Short telomeres also contribute to genome instability and are a hallmark of many cancers. There are severa...

متن کامل

Improving qPCR telomere length assays: Controlling for well position effects increases statistical power.

OBJECTIVES Telomere length (TL) is commonly measured using quantitative PCR (qPCR). Although, easier than the southern blot of terminal restriction fragments (TRF) TL measurement method, one drawback of qPCR is that it introduces greater measurement error and thus reduces the statistical power of analyses. To address a potential source of measurement error, we consider the effect of well positi...

متن کامل

TRF1 is a critical trans-acting factor required for de novo telomere formation in human cells.

The duplex telomere repeat (TTAGGG)(n) is an essential cis-acting element of the mammalian telomere, and an exogenous telomere repeat can induce chromosome breakage and de novo telomere formation at the site of a break (telomere seeding). Telomere seeding requires the telomere repeat (TTAGGG)(n) more stringently than does an in vitro telomerase assay, suggesting that it reflects the activity of...

متن کامل

Identification and characterization of a putative telomere end-binding protein from Tetrahymena thermophila.

Telomeric DNA of Tetrahymena thermophila consists of a long stretch of (TTGGGG)n double-stranded repeats with a single-stranded (TTGGGG)2 3' overhang at the end of the chromosome. We have identified and characterized a protein that specifically binds to a synthetic telomeric substrate consisting of duplex DNA and the 3' telomeric repeat overhang. This protein is called TEP (telomere end-binding...

متن کامل

Small-scale telomere repeat sequence content assay using pyrophosphorolysis coupled with ATP detection.

Studies of telomere length have been carried out in diverse areas of research. However, current methods to measure telomeres are cumbersome and not amenable to high-throughput analyses. Using a coupled pyrophosphorolysis/trans-phosphorylation reaction, we have developed a novel assay to quantitate telomere sequence content in a single tube or 96-well format. The method uses a telomere-specific ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016