Correction: Assessment of the Coronary Venous System Using 256-Slice Computed Tomography
نویسندگان
چکیده
PURPOSE To investigate the coronary venous system and its relation to adjacent structures using 256-slice computed tomography (CT). MATERIALS AND METHODS The study consisted of 102 patients who underwent coronary CT angiography (CTA) using 256-slice CT. For each patient, the coronary venous system and its relation to adjacent structures were evaluated. The appropriate locations and diameters of the posterior interventricular vein (PIV), posterior vein of the left ventricle (PVLV) and the left marginal vein (LMV) were detected. The paired student's t test was used to evaluate the difference between the diameter of the coronary sinus (CS) ostium in anteroposterior direction and that in superoinferior direction. RESULTS The CS, great cardiac vein (GCV), PIV, and anterior interventricular vein (AIV) were visualized in all cases. It was possible to evaluate at least one main vein with adequate caliber and regular course for cardiac resynchronization therapy (CRT) in 96.1% of these cases. The diameter of the CS ostium in superoinferior direction (11.7±2.1 mm) was larger than that in anteroposterior direction (9.0±2.0 mm) (t = 13.511, P<0.05). For the majority of the cases, the CS-GCV was located above the level of the mitral valve annulus (MVA), while the left circumflex coronary artery (LCX) was coursed between the CS-GCV and the MVA. LMV had more intersection with the circumflex or circumflex marginal than PVLV. CONCLUSION 256-slice CT provides superior noninvasive evaluation of the coronary venous system which has important clinical implications.
منابع مشابه
Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study
Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...
متن کامل[Non-invasive assessment of coronary artery bypass grafts by computed tomography: comparison with conventional coronary angiography].
INTRODUCTION AND OBJECTIVES Although it has been demonstrated that the diagnostic accuracy of computed tomography in the non-invasive assessment of major epicardial coronary arteries is high, only a few studies have evaluated the technique's reliability in assessing coronary artery bypass grafts. The aim of this study was to determine the diagnostic accuracy of multidetector computed tomography...
متن کاملQualitative and Quantitative Assessment of Adenosine Triphosphate Stress Whole-Heart Dynamic Myocardial Perfusion Imaging Using 256-Slice Computed Tomography
BACKGROUND The aim of this study was to investigate the correlation of the qualitative transmural extent of hypoperfusion areas (HPA) using stress dynamic whole-heart computed tomography perfusion (CTP) imaging by 256-slice CT with CTP-derived myocardial blood flow (MBF) for the estimation of the severity of coronary artery stenosis. METHODS AND RESULTS Eleven patients underwent adenosine tri...
متن کاملCoronary Artery Disease Diagnostic Performance of 64- versus 256-Slice Computed Tomography Coronary Angiography Compared with Conventional Coronary Angiography in Patients with Suspected Coronary Artery Disease
Purpose: The newer 256-slice computed tomography coronary angiography (CTCA) has the capability of improving diagnostic performance in the detection of obstructive coronary artery disease (CAD) compared to 64-slice CTCA. The aim of this study was to compare the diagnostic performance of 64versus 256-slice CTCA in two similar populations. Methods: Our study included 120 consecutive patients who ...
متن کاملOptimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality
Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2014