Automated solid-phase extraction and measurement of perfluorinated organic acids and amides in human serum and milk.

نویسندگان

  • Zsuzsanna Kuklenyik
  • John Adam Reich
  • Jason S Tully
  • Larry L Needham
  • Antonia M Calafat
چکیده

Organic fluorochemicals are used in multiple commercial applications including surfactants, lubricants, paints, polishes, food packaging, and fire-retarding foams. Recent scientific findings suggest that several perfluorochemicals (PFCs), a group of organic fluorochemicals, are ubiquitous contaminants in humans and animals world wide. Furthermore, concern has increased about the toxicity of these compounds. Therefore, monitoring human exposure to PFCs is important. We have developed a high-throughput method for measuring trace levels of 13 PFCs (2 perfluorosulfonates, 8 perfluorocarboxylates, and 3 perfluorosulfonamides) in serum and milk using an automated solid-phase extraction (SPE) cleanup followed by high-performance liquid chromatography-tandem mass spectrometry. The method is sensitive, with limits of detection between 0.1 and 1 ng in 1 mL of serum or milk, is not labor intensive, involves minimal manual sample preparation, and uses a commercially available automated SPE system. Our method is suitable for large epidemiologic studies to assess exposure to PFCs. We measured the serum levels of these 13 PFCs in 20 adults nonoccupationally exposed to these compounds. Nine of the PFCs were detected in at least 75% of the subjects. Perfluorooctanesulfonate (PFOS), perfluorohexanesulfonate (PFHxS), 2-(N-methylperfluorooctane-sulfonamido)acetate (Me-PFOSA-AcOH), perfluorooctanoate (PFOA), and perfluorononanoate (PFNA) were found in all of the samples. The concentration order and measured levels of PFOS, PFOA, Me-PFOSA-AcOH, and PFHxS compared well with human serum levels previously reported. Although no human data are available for the perfluorocarboxylates (except PFOA), the high frequency of detection of PFNA and other carboxylates in our study suggests that human exposure to long-alkyl-chain perfluorocarboxylates may be widespread. We also found PFOS in the serum and milk of rats administered PFOS by gavage, but not in the milk of rats not dosed with PFOS. Furthermore, we did not detect most PFCs in two human milk samples. These findings suggest that PFCs may not be as prevalent in human milk as they are in serum. Additional studies are needed to determine whether environmental exposure to PFCs can result in PFCs partitioning into milk. Large epidemiological studies to determine the levels of PFCs among the U.S. general population are warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of 18 perfluorinated organic acids and amides in human serum using on-line solid-phase extraction.

We have developed an on-line solid-phase extraction (SPE) method coupled to high-performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) for measuring trace levels of 18 perfluorinated chemicals (3 perfluorosulfonates, 8 perfluorocarboxylates, 7 perfluorosulfonamides) in serum. Without protein precipitation, only dilution with 0.1 M formic acid, one aliquot of 100 microL of se...

متن کامل

Health risks in infants associated with exposure to perfluorinated compounds in human breast milk from Zhoushan, China.

Recent studies have reported the ubiquitous distribution of perfluorinated compounds (PFCs), especially perfluorooctanesulfonate (PFOS) and perfluorooctanoic acid (PFOA), in wildlife and human whole blood or serum. In 2003 a solid phase extraction method was developed, which allowed the measurement of PFCs in human breast milk. In the present study, PFCs in samples of human breast milk from 19 ...

متن کامل

Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples

Objective(s):The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v) at the flow...

متن کامل

Sensitive Simultaneous Measurement of Metformin and Linagliptin in Plasma Samples by Couple of Nano Graphene Oxide-based Dispersive Solid Phase Extraction Method and Liquid Chromatography

A simple, rapid, and ultra sensitive dispersive solid phase extraction based on nano graphene oxide was developed for simultaneous measurement of trace amounts of metformin (MET) and linagliptin (LIN) in plasma samples by HPLC-UV-Vis. Affecting factors on the extraction of these drugs, including adsorbent weight, extraction time, organic solvent type, desorption situations, and composition of s...

متن کامل

Sensitive Simultaneous Measurement of Metformin and Linagliptin in Plasma Samples by Couple of Nano Graphene Oxide-based Dispersive Solid Phase Extraction Method and Liquid Chromatography

A simple, rapid, and ultra sensitive dispersive solid phase extraction based on nano graphene oxide was developed for simultaneous measurement of trace amounts of metformin (MET) and linagliptin (LIN) in plasma samples by HPLC-UV-Vis. Affecting factors on the extraction of these drugs, including adsorbent weight, extraction time, organic solvent type, desorption situations, and composition of s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental science & technology

دوره 38 13  شماره 

صفحات  -

تاریخ انتشار 2004