A prospective randomised controlled study comparing bipolar plasma vaporisation of the prostate to monopolar transurethral resection of the prostate
نویسندگان
چکیده
OBJECTIVES To compare the safety and efficacy of bipolar transurethral plasma vaporisation (B-TUVP) as an alternative to the 'gold standard' monopolar transurethral resection of the prostate (M-TURP) for the treatment of benign prostatic hyperplasia (BPH) in a prospective randomised controlled study. PATIENTS AND METHODS In all, 82 patients indicated for prostatectomy were assigned to two groups, group I (40 patients) underwent B-TUVP and group II (42 patients) underwent M-TURP. The safety of both techniques was evaluated by reporting perioperative changes in serum Na+, serum K+, haematocrit (packed cell volume), and any perioperative complications. For the efficacy assessment, patients were evaluated subjectively by comparing the improvement in International Prostate Symptom Score and objectively by measuring the maximum urinary flow rate (Qmax) and post-void residual urine volume (PVR) before and after the procedures. RESULTS In group II, there was a significant perioperative drop in serum Na+ (from 137.5 to 129.4 mmol/L) and haematocrit (from 42.9% to 38.2%) (both P < 0.001). Moreover, one patient in group II had TUR syndrome. The remote postoperative complication rate was (15%) in group I and comprised of stress urinary incontinence (5%), bladder outlet obstruction (5%), and residual adenoma (5%). In group II, the remote postoperative complication rate was (4.8%), as two patients developed urethral stricture. There were statistically significant improvements in micturition variables postoperatively in both arms, but the magnitude of improvement was statistically more significant in group II. CONCLUSION B-TUPV seems to be safer than M-TURP; however, the lack of a tissue specimen and the relatively high retreatment rate are major disadvantages of the B-TUVP technique. Moreover, M-TURP appears to be more effective than B-TUPV and its safety can be improved by careful case selection and adequate haemostasis.
منابع مشابه
Day care bipolar transurethral resection vs photoselective vaporisation under sedoanalgesia: A prospective, randomised study of the management of benign prostatic hyperplasia
Objective To conduct a prospective randomised study comparing the safety, effectiveness and treatment outcomes in patients undergoing bipolar transurethral resection of the prostate (bTURP) and photoselective vaporisation of the prostate (PVP) under sedoanalgesia, as sedoanalgesia is a safe and effective technique suitable for minimally invasive endourological procedures and although studies ha...
متن کاملSystematic review and meta-analysis of the clinical effectiveness of bipolar compared with monopolar transurethral resection of the prostate (TURP).
To compare monopolar and bipolar transurethral resection of the prostate (TURP) for clinical effectiveness and adverse events. We conducted an electronic search of MEDLINE, Embase, CENTRAL, Science Citation Index, and also searched reference lists of articles and abstracts from conference proceedings for randomised controlled trials (RCTs) comparing monopolar and bipolar TURP. Two reviewers ind...
متن کاملComparison of the haemostatic properties of conventional monopolar and bipolar transurethral resection of the prostate in patients on oral anticoagulants
INTRODUCTION The aim of study is comparing the haemostatic properties of conventional monopolar resection (TURP) and bipolar transurethral resection in saline (TURIS) of the prostate in patients under chronic oral anticoagulants. MATERIAL AND METHODS Out of a cohort group of 550 endoscopic resections for bladder outlet obstruction, 176 patients on chronic oral anticoagulant therapy required e...
متن کاملFive-Year Follow-Up Results of a Randomized Controlled Trial Comparing Bipolar Plasmakinetic and Monopolar Transurethral Resection of the Prostate
PURPOSE To report the 5-year follow-up results of a randomized controlled trial comparing bipolar transurethral resection of the prostate (TURP) with standard monopolar TURP for the treatment of benign prostatic obstruction (BPO). MATERIALS AND METHODS A total of 220 patients were randomized to bipolar plasmakinetic TURP (PK-TURP) or monopolar TURP (M-TURP). Catheterization time was the prima...
متن کاملTransurethral resection of prostate: a comparison of standard monopolar versus bipolar saline resection.
INTRODUCTION Transurethral resection syndrome is an uncommon but potentially life threatening complication. Various irrigating solutions have been used, normal saline being the most physiological. The recent availability of bipolar cautery has permitted the use of normal saline irrigation. MATERIAL AND METHODS In a randomized prospective study, we compared the safety and efficacy of bipolar c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -
تاریخ انتشار 2016