Simulation of the impact of refractive surgery ablative laser pulses with a flying-spot laser beam on intrasurgery corneal temperature.
نویسندگان
چکیده
PURPOSE To evaluate ablation algorithms and temperature changes in laser refractive surgery. METHODS The model (virtual laser system [VLS]) simulates different physical effects of an entire surgical process, simulating the shot-by-shot ablation process based on a modeled beam profile. The model is comprehensive and directly considers applied correction; corneal geometry, including astigmatism; laser beam characteristics; and ablative spot properties. RESULTS Pulse lists collected from actual treatments were used to simulate the temperature increase during the ablation process. Ablation efficiency reduction in the periphery resulted in a lower peripheral temperature increase. Steep corneas had lesser temperature increases than flat ones. The maximum rise in temperature depends on the spatial density of the ablation pulses. For the same number of ablative pulses, myopic corrections showed the highest temperature increase, followed by myopic astigmatism, mixed astigmatism, phototherapeutic keratectomy (PTK), hyperopic astigmatism, and hyperopic treatments. CONCLUSIONS The proposed model can be used, at relatively low cost, for calibration, verification, and validation of the laser systems used for ablation processes and would directly improve the quality of the results.
منابع مشابه
Effects of Laser Physical Parameters on Lesion Size in Retinal Photocoagulation Surgery: Clinical OCT and Experimental Study
Introduction: The aim of the present study was to determine burn intensity in retinal laser photocoagulation based on laser parameters; wavelength, power, beam size and pulse duration, using Optical Coherence Tomography (OCT), fundus camera, physical eye model and computer simulation in a clinical study.Materials and Methods: Participants were 10 adult patients between 50-80 years with prolifer...
متن کاملExcimer laser correction of hyperopia, hyperopic and mixed astigmatism: past, present, and future.
The broad acceptance of "spot scanning" or "flying spot" excimer lasers in the last decade has enabled the domination of corneal ablative laser surgery over other refractive surgical procedures for the correction of hyperopia, hyperopic and mixed astigmatism. This review outlines the most important reasons why the ablative laser correction of hyperopia, hyperopic and mixed astigmatism for many ...
متن کاملThe Alcon/Summit/Autonomous perspective on fixed vs. variable spot ablation.
The LADARVision system utilizes a small fixed diameter excimer laser beam coupled with a high fidelity eye tracking system to perform wavefront-guided refractive surgery. The fixed small beam provides a consistent ablation per pulse. By delivering many identical pulses in a predetermined pattern, which includes an optimized custom blend zone, the laser is able to ablate complex (higher order) c...
متن کاملRefractive Error and Anterior Segment Parametric Changes in Patients with Posterior Capsular Opacification after Nd: YAG Laser Posterior Capsulotomy
Background and Objective: Cataract is one of the most common causes of blindness in the world, and posterior capsular opacification (PCO) is the most common complication after cataract surgery. Nd: YAG laser posterior capsulotomy is a standard method for the treatment of PCO. The aim of this study was to investigate the effects of Yas laser capsulotomy on anterior segment parameters and lenticu...
متن کاملNumerical simulation of laser beam welding of Ti6Al4V sheet
This paper was aimed to report the 3D finite element analysis simulation of laser welding process of Ti6Al4V 1.7 mm sheets in butt joint in order to predict the temperature distribution, hardness, and weld geometry. The butt-joint welds were made using CO2 laser with the maximum power of 2.2 kW in the continuous wave mode. A part of the experimental work was carried out to verify the weld geome...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 52 6 شماره
صفحات -
تاریخ انتشار 2011