Preliminary comparison of the registration effect of 4D-CBCT and 3D-CBCT in image-guided radiotherapy of Stage IA non–small-cell lung cancer
نویسندگان
چکیده
In this study, we compared the registration effectiveness of 4D cone-beam computed tomography (CBCT) and 3D-CBCT for image-guided radiotherapy in 20 Stage IA non-small-cell lung cancer (NSCLC) patients. Patients underwent 4D-CBCT and 3D-CBCT immediately before radiotherapy, and the X-ray Volume Imaging software system was used for image registration. We performed automatic bone registration and soft tissue registration between 4D-CBCT or 3D-CBCT and 4D-CT images; the regions of interest (ROIs) were the vertebral body on the layer corresponding to the tumor and the internal target volume region. The relative displacement of the gross tumor volume between the 4D-CBCT end-expiratory phase sequence and 4D-CT was used to evaluate the registration error. Among the 20 patients (12 males, 8 females; 35-67 years old; median age, 52 years), 3 had central NSCLC and 17 had peripheral NSCLC, 8 in the upper or middle lobe and 12 in the lower lobe (maximum tumor diameter range, 18-27 mm). The internal motion range in three-dimensional space was 12.52 ± 2.65 mm, accounting for 47.8 ± 15.3% of the maximum diameter of each tumor. The errors of image-guided registration using 4D-CBCT and 3D-CBCT on the x (left-right), y (superior-inferior), z (anterior-posterior) axes, and 3D space were 0.80 ± 0.21 mm and 1.08 ± 0.25 mm, 2.02 ± 0.46 mm and 3.30 ± 0.53 mm, 0.52 ± 0.16 mm and 0.85 ± 0.24 mm, and 2.25 ± 0.44 mm and 3.59 ± 0.48 mm (all P < 0.001), respectively. Thus, 4D-CBCT is preferable to 3D-CBCT for image guidance in small pulmonary tumors because 4D-CBCT can reduce the uncertainty in the tumor location resulting from internal motion caused by respiratory movements, thereby increasing the image-guidance accuracy.
منابع مشابه
Accuracy and inter-observer variability of 3D versus 4D cone-beam CT based image-guidance in SBRT for lung tumors
BACKGROUND To analyze the accuracy and inter-observer variability of image-guidance (IG) using 3D or 4D cone-beam CT (CBCT) technology in stereotactic body radiotherapy (SBRT) for lung tumors. MATERIALS AND METHODS Twenty-one consecutive patients treated with image-guided SBRT for primary and secondary lung tumors were basis for this study. A respiration correlated 4D-CT and planning contours...
متن کاملDifference in performance between 3D and 4D CBCT for lung imaging: a dose and image quality analysis
The study was to describe and to compare the performance of 3D and 4D CBCT imaging modalities by measuring and analyzing the delivered dose and the image quality. The 3D (Chest) and 4D (Symmetry) CBCT Elekta XVI lung IGRT protocols were analyzed. Dose profiles were measured with TLDs inside a dedicated phantom. The dosimetric indicator cone-beam dose index (CBDI) was evaluated. The image qualit...
متن کاملRespiratory correlated cone beam CT.
A cone beam computed tomography (CBCT) scanner integrated with a linear accelerator is a powerful tool for image guided radiotherapy. Respiratory motion, however, induces artifacts in CBCT, while the respiratory correlated procedures, developed to reduce motion artifacts in axial and helical CT are not suitable for such CBCT scanners. We have developed an alternative respiratory correlated proc...
متن کاملTarget localization of 3D versus 4D cone beam computed tomography in lipiodol-guided stereotactic radiotherapy of hepatocellular carcinomas
BACKGROUND Aim of this study was to comparatively evaluate the accuracy of respiration-correlated (4D) and uncorrelated (3D) cone beam computed tomography (CBCT) in localizing lipiodolized hepatocellular carcinomas during stereotactic body radiotherapy (SBRT). METHODS 4D-CBCT scans of eighteen HCCs were acquired during free-breathing SBRT following trans-arterial chemo-embolization (TACE) wit...
متن کاملDeformable registration of the inflated and deflated lung in cone-beam CT-guided thoracic surgery: initial investigation of a combined model- and image-driven approach.
PURPOSE Surgical resection is the preferred modality for curative treatment of early stage lung cancer, but localization of small tumors (<10 mm diameter) during surgery presents a major challenge that is likely to increase as more early-stage disease is detected incidentally and in low-dose CT screening. To overcome the difficulty of manual localization (fingers inserted through intercostal po...
متن کامل