Efficient off-resonance correction for spiral imaging.

نویسندگان

  • K S Nayak
  • C M Tsai
  • C H Meyer
  • D G Nishimura
چکیده

A new spiral imaging technique incorporates the acquisition of a field map into imaging interleaves. Variable density spiral trajectories are designed to oversample the central region of k-space, and interleaves are acquired at two different echo times. A field map is extracted from this data and multifrequency reconstruction is used to form an off-resonance corrected image using the entire dataset. Simulation, phantom, and in vivo results indicate that this technique can be used to achieve higher image and/or field map spatial resolution compared to conventional techniques. Magn Reson Med 45:521-524, 2001.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Block regional off-resonance correction (BRORC): a fast and effective deblurring method for spiral imaging.

One primary disadvantage of spiral imaging is blurring artifact due to off-resonance effects. The conventional frequency segmented off-resonance correction method that is performed over the entire image is computationally intense due to the large number of fast Fourier transforms (FFTs) required. Here, a new fast off-resonance correction method, block regional off-resonance correction (BRORC), ...

متن کامل

Spiral water-fat imaging with integrated off-resonance correction on a clinical scanner.

PURPOSE To integrate water-fat-resolved spiral gradient-echo imaging with off-resonance correction into a clinical MR scanner and to evaluate its basic feasibility and performance. MATERIALS AND METHODS Three-point chemical shift imaging was implemented with forward and strongly T(2)*-weighted reverse spiral sampling and with off-resonance correction after water-fat separation. It was applied...

متن کامل

Fast conjugate phase image reconstruction based on a Chebyshev approximation to correct for B0 field inhomogeneity and concomitant gradients.

Off-resonance effects can cause image blurring in spiral scanning and various forms of image degradation in other MRI methods. Off-resonance effects can be caused by both B0 inhomogeneity and concomitant gradient fields. Previously developed off-resonance correction methods focus on the correction of a single source of off-resonance. This work introduces a computationally efficient method of co...

متن کامل

Correction of physiologically induced global off-resonance effects in dynamic echo-planar and spiral functional imaging.

In functional magnetic resonance imaging, a rapid method such as echo-planar (EPI) or spiral is used to collect a dynamic series of images. These techniques are sensitive to changes in resonance frequency which can arise from respiration and are more significant at high magnetic fields. To decrease the noise from respiration-induced phase and frequency fluctuations, a simple correction of the "...

متن کامل

Efficient T2*- Contrast Manipulations in 3D Abdominal Imaging using Autocorrected Forward/Reverse Spiral MRI

Introduction Besides large volume coverage and short total scan times, image contrast is very important in abdominal MRI. Fat suppression is often required and different T2* weightings are desired for different contrasts in gradient echo acquisitions. Very short and very long TEs facilitate the relevant contrasts of interest for the detection of dedicated contrast media, hemorrhage, iron deposi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 45 3  شماره 

صفحات  -

تاریخ انتشار 2001