PURPOSE To evaluate posterior capsule opacification (PCO) in humans after cataract surgery with intraocular lens (IOL) implantation, by using optical coherence tomography (OCT-1). METHODS Sixty-six eyes with PCO and 20 eyes with a normal posterior capsule were analyzed. A 3-mm-long horizontal scan of the posterior capsule was obtained. Measurements at three points and their average were recorded. Intraoperator and interoperator reliabilities were assessed. Investigated was peak intensity (PI) and posterior capsule thickening (PCT), with PCT indicating the distance between two reflectivity spikes, with an approximate axial resolution of 10 microm. Results were compared with visual acuity (VA) and PCO type. RESULTS Intraoperator reliability was 0.59 and 0.97 for average PI and PCT, respectively. The interoperator concordance correlation coefficient was 0.70 and 0.82 for average PI and PCT, respectively. Median (interquartile range) intensities of the reflectivity spike were 16.88 (dB) (range, 12.88-20.41) and 11.9 (8.58-14.28), respectively, in the PCO and control eyes (P = 0.001). PCT was found in PCO eyes (median: 86.13 microm; range, 46.33-115.33), whereas no second spike appeared in control eyes (P = 0.001). The area under the receiver operating characteristic curve of the average PCT for differentiating pearl-type from fibrosis-type PCO was 0.87 (P = 0.001). For a cutoff point of 55.3 microm, the sensitivity was 97.5%, and the specificity was 69%. Worse VA correlated significantly only with larger PCT (r(o) = 0.66; P = 0.01). CONCLUSIONS OCT-1 appears useful to quantitate PCO. In addition, this system seems to discriminate between different types of PCO. PCT may be a previously unrecognized factor in VA degradation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Visual Quality Assessment of Posterior Capsule Opacification Using Optical Quality Analysis System (OQAS)

Objective To evaluate intraocular scattering in eyes with posterior capsule opacification by means of an objective scatter index (OSI) obtained from double-pass images of optical quality assessment system (OQAS TM II) and to determine the indication for laser capsulotomy when patients report visual disturbances without decreased visual acuity. Methods In this prospective, observational, and n...

متن کامل

Optical coherence tomography for an in-vivo study of posterior-capsule-opacification types and their influence on the total-pulse energy required for Nd:YAG capsulotomy: a case series

BACKGROUND Posterior capsule opacification (PCO) is the most common post-operative complication associated with cataract surgery and is mostly treated with Nd:YAG laser capsulotomy. Here, we demonstrate the use of high-resolution spectral-domain optical coherence tomography (OCT) as a technique for PCO analysis. Additionally, we evaluate the influence of PCO types and the distance between the i...

متن کامل

Does Posterior Capsule Opacification Affect the Results of Diagnostic Technologies to Evaluate the Retina and the Optic Disc?

The visual outcome obtained after cataract removal may progressively decline because of posterior capsular opacification (PCO). This condition can be treated by creating an opening in the posterior lens capsule by Nd:YAG laser capsulotomy. PCO optical imperfections cause several light reflection, refraction, and diffraction phenomena, which may interfere with the functional and structural tests...

متن کامل

[Influence of topical latanoprost on foveal thickness in eyes that underwent uneventful cataract surgery].

PURPOSE To study prospectively using optical coherence tomography whether topical latanoprost induces retinal disorders in patients that underwent cataract surgery. METHODS Randomized, masked-observer, one-month clinical trial. Pseudophakic patients were treated with latanoprost (n=10) or lubricant drop q.d. (control group) (n=10). Half of the patients of each group presented ruptured posteri...

متن کامل

Anterior segment optical coherence tomography for demonstrating posterior capsular rent in posterior polar cataract

AIMS/PURPOSE To report the preoperative use of anterior segment optical coherence tomography (AS-OCT) for the determination of pre-existing posterior capsule defect in patients with posterior polar cataract. METHODS Three patients presented with posterior polar cataract and were evaluated preoperatively using AS-OCT, revealing in one patient intact posterior capsule and in the other two a pre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 46 11  شماره 

صفحات  -

تاریخ انتشار 2005