Multivariate Optimization in the Direct Determination of Antimony and Chromium in Serum Samples by Graphite Furnace Atomic Absorption Spectrometry
نویسندگان
چکیده
Methods for direct determination of antimony and chromium in human serum by Graphite Furnace Atomic Absorption Spectrometry (GF AAS) were proposed in this work. The samples were diluted in 1:1 with nitric acid 1% v/v and Triton® X-100 0.1% v/v. The optimization of the instrumental conditions was done using a multivariate approach. A factorial design (2) was employed to investigate the tendency of the most intense absorvance signal for each analyte. Permanent zirconium modifier (500 μg) demonstrated better performance for use as a chemical modifier for antimony while for chromium, the best modifier was permanent tungsten. A Central Composed Design (CCD) was used to obtain the optimum conditions through the methodology of surface response, resulting in the best temperatures of 700 oC and 2400 oC for pyrolysis and atomization temperatures for antimony and 1600 oC and 2504 oC for chromium, respectively. The method allowed the determination of antimony with a curve varying from 0 to 30.0 μg L. Recovery studies for three concentration levels (n=7 for each level, prepared and read in three consecutive days) presented results of 101 ± 3 % for Sb and 93 ± 7 % for Cr. The detection limit was 0.3 g L for Cr and Sb. Intra and inter-assay studies, according to coefficients of variation results, were 2.6-2.8 % and 4.3-5.6 % for Sb and 3.0-5.5 % and 6.2-9.9 % for Cr, respectively. The method was applied for the determination of antimony in 60 samples obtaining concentrations from < LOD to 10.9 μg L and for Cr with concentrations between < LOD to 41.8 μg L.
منابع مشابه
Utilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples
In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...
متن کاملGRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY WITH MAlIlRIX MODIFICATION FOR DETERMINATION OF LEAD IN DRINKING WATER
An amoniumvanadate plus sodium molybdate mixed modifier Graphite Furnace Atomic Absorption Spectrometric method has been developed for determination of traces of lead in drinking water. The concentration of lead in the sample is obtained by direct comparison to linear working graph prepared from aqueous standards in the modifier medium, The results indicate the better performance of the pro...
متن کاملAir-assisted Liquid Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry for Preconcentration and Determination of Trace Amount of Co(II) and Ni(II) Ions in Water Samples
A simple, rapid and efficient method has been developed for the extraction, preconcentration and determination of cobalt (II) and nickel (II) ions in water samples by air-assisted liquid-liquid microextraction (AALLME) coupled with graphite furnace atomic absorption spectrometry (GFAAS). In the proposed method, much less volume of an organic solvent was used as the extraction solvent in the abs...
متن کاملDetermination and Levels of Chromium in French Wine and Grapes by Graphite Furnace Atomic Absorption Spectrometry
An accurate and precise method for direct determination of chromium in wine using graphite furnace atomic absorption spectrometry (GFAAS) is described. The method was also applied to grape samples treated by previous acid mineralization. A total of 79 wine samples from different regions in France and 12 grape samples of different varieties were analyzed. Chromium levels ranged from 7.0 to 90.0 ...
متن کاملDEVELOPMENT OF A METHOD FOR ALUMINIUM DETERMINATION IN SERUM AND DIALYSIS FLUID BY FLAMELESS ATOMIC ABSORPTION WITH GRAPHITE FURNACE
Aluminium determination was carried out in serum and dialysis fluid by a simple and reliable method of nameless atomic absorption with graphite furnace . . No preparatory procedures are required for water and dialysis fluid. In this method serum was mixed with 0.2% HNO, to allow complete combustion of the samples in order to improve analytical precision. The method has a sensitivity of 15 p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015