OBJECTIVE This study aimed to evaluate the inter- and intra observer reproducibility of the radiographic score of consolidation of the tibia shaft fractures. METHODS Fifty-one sets of radiographs in anteroposterior (AP) and profile (P) of the tibial shaft treated with intramedullary nail were obtained. The analysis of X-rays was performed in two stages, with a 21-day interval between assessments by a group of nine evaluators. To evaluate the reproducibility of RUST score between the evaluators, the intra-class correlation coefficient (ICC) with a 95% confidence interval was used. ICC values range from +1, representing perfect agreement, to -1, complete disagreement. RESULTS There was a significant correlation among all evaluators: ICC = 0.87 (95% CI 0.81 to 0.91). The intraobserver agreement proved to be substantial with ICC = 0.88 (95% CI 0.85 to 0.91). CONCLUSION This study confirms that the RUST scale shows a high degree of reliability and agreement.
منابع مشابه
The radiographic union scale in tibial (RUST) fractures
OBJECTIVES The radiographic union score for tibial (RUST) fractures was developed by Whelan et al to assess the healing of tibial fractures following intramedullary nailing. In the current study, the repeatability and reliability of the RUST score was evaluated in an independent centre (a) using the original description, (b) after further interpretation of the description of the score, and (c) ...
متن کاملThe Role of Biplanar Distal Locking in Intramedullary Nailing of Tibial Shaft Fractures
Background: To compare the union times of the uncomplicated tibial shaft fractures, which were distally locked by twocoronal and one sagittal screws and by only two coronal screws.Methods: 45 patients with tibial shaft treated with intramedullary nailing included in this study. 23 of 45 fractureswere treated with uniplanar two distal interlocking (Group 1) and 22 fractures were treated with bip...
متن کاملTreatment of Open Tibial Fractures: Convert-ing or Continuing External Fixation?
Background: The treatment of open tibial fractures is still an orthopaedic challenge and full of complications. In many cases the use of external fixator that has been known as a non-union machine is obligatory with a high incidence of pin track infection and other complications. The aim of this study was to compare the use of external fixation as a definite method for treatment of open tibial ...
متن کاملEffectiveness of Minimally Invasive Plate Osteosynthesis (MIPO) on Comminuted Tibial or Femoral Fractures
Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO), has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were opera...
متن کاملLong- Stem Total Knee Arthroplasty for Proximal Tibial Stress Fractures in the Elderly Patients
Background: Presentation of proximal tibia stress fracture is not infrequent among elderly patients due to their poorbone stock. Optimal management of patients with severe gonarthrosis of the knee and concurrent tibial stress fracture isnot known yet. In this study we report the outcome of primary total knee arthroplasty (TKA) using stemmed componentsin elderly patients.Methods: Between 2009 an...