Variation in the arterial to end-tidal PCO2 difference during one-lung thoracic anaesthesia.

نویسندگان

  • P C Ip Yam
  • P A Innes
  • M Jackson
  • S L Snowdon
  • G N Russell
چکیده

We have measured the arterial to end-tidal PCO2 difference (PaCO2-PE'CO2) in 22 patients undergoing pulmonary resection in the lateral thoracotomy position during two-lung ventilation (TLV) and after transition to one-lung ventilation (OLV). With OLV for each patient, the practice of correcting the estimate by an initial measurement of (PaCO2-PE'CO2) was evaluated by subtracting the initial (PaCO2-PE'CO2) from subsequent values measured at 10-min intervals. Net (uncorrected) and corrected differences during OLV were analysed using ANOVA. (PaCO2-PE'CO2) values during TLV and OLV were similar: mean (SD) 1.3 (0.6) kPa and 1.2 (0.7) kPa, respectively (ns). Mean (PaCO2-PE'CO2) varied in the range 0.2-2.5 kPa, while maximum (PaCO2-PE'CO2) was 0.3-2.8 kPa. The mean (SD) of 133 pairs of measurements with OLV was 1.1 (0.7) kPa. Even after correction, mean (PaCO2-PE'CO2) varied in the range -0.7 to 0.8 kPa; individual extreme values were from -1.3 to 1.7 kPa. Variation between patients was found to be greater than variation within patients for both net and corrected differences (F ratio = 37.0 and 10.9, respectively), although calculating a corrected difference did reduce variation between patients from a mean square value of 2.44 to 0.61. The wide variation in (PaCO2-PE'CO2) suggests that the accuracy of estimation of PaCO2 by monitoring PE'CO2, although improved by the use of a corrected difference, remains questionable during OLV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of arterial PCO2 during high frequency jet ventilation. Studies in the dog.

The arterial to end-tidal PCO2 difference (PaCO2-PE'CO2) was measured in five anaesthetized dogs during controlled ventilation at 0.25 Hz (15 b.p.m.) and during high frequency jet ventilation at 1, 3 and 5 Hz. Because of the slow response of the infra-red carbon dioxide analyser, satisfactory recordings of end-tidal carbon dioxide could not be obtained at frequencies greater than 1 Hz. The inte...

متن کامل

Effects of lung surgery and one-lung ventilation on pulmonary arterial pressure, venous admixture and immediate postoperative lung function.

We studied 17 patients, with unilateral lesions in lung or thoracic wall, during thoracotomy performed in the full lateral position. Balanced anaesthesia was used with pethidine and 50% nitrous oxide, in oxygen. The procedure included a period of one-lung ventilation (OLV). Haemodynamic and gas exchange measurements were performed before and after pleurotomy, during OLV, after re-expansion of t...

متن کامل

The Diagnostic Value of End-tidal Carbon Dioxide (EtCO2) and Alveolar Dead Space (AVDS) in Patients with Suspected Pulmonary Thrombo-embolism (PTE)

Introduction: Capnography, is an easy, fast and practical method which its application in the diagnosis of Pulmonary Thromboendarterectomy (PTE) has recently been studied. This study aimed to assess the diagnostic value of end-tidal CO2 (ETCO2) and the alveolar dead space (AVDS) in the diagnosis of patients suspected to PTE who have been referred to the emergency department. Materials and Metho...

متن کامل

Arterial to end-tidal carbon dioxide tension difference during anaesthesia in early pregnancy.

Sixteen patients requiring general anaesthesia for termination of pregnancy by dilatation and evacuation of the uterus were studied. Arterial and end-tidal carbon dioxide tensions were determined during anaesthesia. The mean arterial to end-tidal carbon dioxide tension difference was 0.07 kPa (-0.02-0.16, 5-95 per cent confidence limits). These results were similar to those observed during Caes...

متن کامل

بررسی همبستگی و میزان توافق نتایج PaCO2 گازهای خون شریانی با CO2 انتهای بازدمی (End-Tidal CO2) توسط کاپنوگرافی در بیماران مبتلا به تشدید حاد بیماری انسدادی ریوی (COPD)

  Background : Chronic Obstructive Pulmonary Disease (COPD) represents a major public health problem. The course of COPD is characterized by episodic periods of worsening symptoms, termed exacerbations. Supplemental oxygen should be given to patients with COPD exacerbation without causing CO2 retention. Arterial blood gas sampling is the gold standard for monitoring adequate oxygenation and for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 72 1  شماره 

صفحات  -

تاریخ انتشار 1994