Development of a microfabricated cytometry platform for characterization and sorting of individual leukocytes.
نویسندگان
چکیده
Organizing leukocytes into high-density arrays makes these cells amenable to rapid optical characterization and subsequent sorting, pointing to clinical and basic science applications. The present paper describes development of a cytometry platform for creating high-density leukocyte arrays and demonstrates retrieval of single cells from the array. Poly(ethylene glycol)(PEG) photolithography was employed to fabricate arrays of microwells composed of PEG hydrogel walls and glass attachment pads 20 microm x 20 microm and 15 microm x 15 microm in size. PEG micropatterned glass surfaces were further modified with cell-adhesive ligands, poly-L-lysine, anti-CD5 and anti-CD19 antibodies, in order to engineer specific cell-surface interactions within the individual wells. Localization of the fluorescently-labeled proteins in the glass attachment pads of PEG microwells was visualized by fluorescence microscopy. Glass slides micropatterned with PEG and cell-adhesive ligands were exposed to T-lymphocytes for 30 min. These anchorage-independent cells became selectively captured in the ligand-modified microwells forming high-density cell arrays. Cell occupancy in the microwells was found to be antibody-dependent, reaching 94.6 +/- 2.3% for microwells decorated with T-cell specific anti-CD5 antibodies. Laser capture microdissection (LCM) was investigated as a method for sorting cells from the array and retrieval of single selected cells was demonstrated.
منابع مشابه
Disposable Microdevices for Dna Analysis and Cell Sorting
We have developed microfabricated devices to size and sort microscopic objects, based on measurement of fluorescent properties. With these devices, we have demonstrated sizing and sorting on various biological entities, ranging from E. Coli cells to single molecules of DNA. The microfabricated devices have several advantages over macroscopic systems, including size, cost and sensitivity. For ex...
متن کاملIntegrating advanced functionality in a microfabricated high-throughput fluorescent-activated cell sorter.
The integration of complete analyses systems "on chip" is one of the great potentials of microfabricated devices. In this study we present a new pressure-driven microfabricated fluorescent-activated cell sorter chip with advanced functional integration. Using this sorter, fluorescent latex beads are sorted from chicken red blood cells, achieving substantial enrichments at a sample throughput of...
متن کاملHormonal regulation of circulating C-reactive protein in men.
increase leukocyte capture, various experimental conditions, such as the antibody fixing time, incubation time, and leukocyte concentration, were optimized. The results for the CD45 immobilization experiments showed that various experimental conditions, such as antibody fixing time, incubation time, and leukocyte concentration, affected the leukocyte capture efficiencies. We identified the foll...
متن کاملTreatment and Correlation With Bond Strength
Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocy...
متن کاملA miniature cytometry platform for capture and characterization of T-lymphocytes from human blood.
Given the clinical and diagnostic importance of blood analysis, there is considerable interest in developing novel miniature devices for rapid characterization of blood constituents. The present paper describes development of a miniature cytometry platform aimed at analysis of T-lymphocytes from peripheral human blood. Microarrays of T-cell-specific antibodies (Abs), including anti-CD3, -CD4, -...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Lab on a chip
دوره 5 1 شماره
صفحات -
تاریخ انتشار 2005